Browse wiki
Jump to navigation
Jump to search
The following summary was received from th … The following summary was received from the licensee via email:</br>On 1240 EDT on 7/29/2020, a Radiographer for Diamond Technical Services discovered that the source for a radiography projector disconnected from the drive cable. The radiation barriers were expanded, additional shielding was laid down, and site personnel were notified to clear the immediate area. No personnel were exposed at the time of the discovery. The source projector is a Sentinel 880D, S/N: 12726 with an Iridium-192 source with an activity of 52.5 Curies. The Operations Manager and Radiation Safety Officer traveled to Alma, WV from their offices in Blairsville, PA with emergency equipment and radiation safety supplies. At 1715 EDT, the source was retrieved and secured in its shielded position. There were no indications of excessive exposures. The preliminary cause of the source disconnection was determined to be fatigue failure. The components will be shipped to QSA for manufacturer evaluation and inspection.or manufacturer evaluation and inspection. +
16:40:00, 29 July 2020 +
54,856 +
14:26:00, 25 August 2020 +
16:40:00, 29 July 2020 +
The following summary was received from th … The following summary was received from the licensee via email:</br>On 1240 EDT on 7/29/2020, a Radiographer for Diamond Technical Services discovered that the source for a radiography projector disconnected from the drive cable. The radiation barriers were expanded, additional shielding was laid down, and site personnel were notified to clear the immediate area. No personnel were exposed at the time of the discovery. The source projector is a Sentinel 880D, S/N: 12726 with an Iridium-192 source with an activity of 52.5 Curies. The Operations Manager and Radiation Safety Officer traveled to Alma, WV from their offices in Blairsville, PA with emergency equipment and radiation safety supplies. At 1715 EDT, the source was retrieved and secured in its shielded position. There were no indications of excessive exposures. The preliminary cause of the source disconnection was determined to be fatigue failure. The components will be shipped to QSA for manufacturer evaluation and inspection.or manufacturer evaluation and inspection. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 25 August 2020 +
37-31259-01 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
16:25:00, 15 January 2021 +
14:26:00, 25 August 2020 +
26.907 d (645.77 hours, 3.844 weeks, 0.885 months) +
16:40:00, 29 July 2020 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.