The following was received from the Common … The following was received from the Commonwealth of Virginia via email:</br>On April 24, 2020, a licensee reported that the shutter of a fixed gauge used to measure the level of material inside a process vessel was stuck in the open position. This incident was identified on April 24, 2020, during the biennial leak testing of the source. The gauge is a Ronan Engineering Company, device (Model SA-1, serial number SO-VA-7063), and Source (Model SA1-F37, serial number M7451), containing 40 mCi of Cs-137. The report indicated that the impacted site personnel were notified immediately and barriers were erected to prevent access to the gauge area. Based on the report, there was no public exposure or environmental release from this event. The licensee has contacted the manufacturer (Ronan Engineering Company) for further investigation and to fix the problem.</br>The Virginia Office of Radiological Health will review the licensee's written report and determine if additional actions are needed to be taken.additional actions are needed to be taken. +
04:00:00, 24 April 2020 +
54,682 +
09:50:00, 27 April 2020 +
04:00:00, 24 April 2020 +
The following was received from the Common … The following was received from the Commonwealth of Virginia via email:</br>On April 24, 2020, a licensee reported that the shutter of a fixed gauge used to measure the level of material inside a process vessel was stuck in the open position. This incident was identified on April 24, 2020, during the biennial leak testing of the source. The gauge is a Ronan Engineering Company, device (Model SA-1, serial number SO-VA-7063), and Source (Model SA1-F37, serial number M7451), containing 40 mCi of Cs-137. The report indicated that the impacted site personnel were notified immediately and barriers were erected to prevent access to the gauge area. Based on the report, there was no public exposure or environmental release from this event. The licensee has contacted the manufacturer (Ronan Engineering Company) for further investigation and to fix the problem.</br>The Virginia Office of Radiological Health will review the licensee's written report and determine if additional actions are needed to be taken.additional actions are needed to be taken. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 27 April 2020 +
041-313-1 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
16:39:56, 15 January 2021 +
09:50:00, 27 April 2020 +
3.243 d (77.83 hours, 0.463 weeks, 0.107 months) +
04:00:00, 24 April 2020 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.