Browse wiki

Jump to navigation Jump to search
On January 27, 2019, at 1913 CST, with theOn January 27, 2019, at 1913 CST, with the University of Missouri-Columbia Research Reactor (MURR) operating at 10 MW in the automatic control mode, the Lead Senior Reactor Operator (LSRO) was conducting surveillance Technical Specification (TS) 4.2.a, which states, 'All control blades, including the regulating blade, shall be verified operable within a shift.' During this shiftily verification of control blade operability, all blades were initially verified operable. However, when banking the control blades to their final position after all blades were satisfactorily tested a few seconds earlier, shim control blade 'A' would not move in the inward direction. The LSRO then immediately shut down the reactor by initiating a manual scram by placing the Master Control Switch 1S1 to the 'TEST' position. The LSRO completed all immediate and subsequent actions of reactor emergency procedure REP-2, 'Reactor Scram,' and verified all shim control blades were fully inserted. </br>The inability to manually insert shim control blade 'A' with Control Rod Operate Switch 1S4, which inserts and withdraws the control blade, is a deviation from TS 3.2.a, which states, 'All control blades, including the regulating blade, shall be operable during reactor operation.' </br>Troubleshooting revealed a problem with an electrical contact on Control Rod Operate Switch 1S4, and it has since been replaced. The reactor has not returned to operation at the time of this email. However, permission from the Reactor Facility Director has been obtained to restart the reactor once scheduled maintenance activities have been completed. A detailed event report will follow within 14 days as required by MURR TS 6.6.c(3).n 14 days as required by MURR TS 6.6.c(3).  +
01:13:00, 28 January 2019  +
53,849  +
15:01:00, 28 January 2019  +
01:13:00, 28 January 2019  +
On January 27, 2019, at 1913 CST, with theOn January 27, 2019, at 1913 CST, with the University of Missouri-Columbia Research Reactor (MURR) operating at 10 MW in the automatic control mode, the Lead Senior Reactor Operator (LSRO) was conducting surveillance Technical Specification (TS) 4.2.a, which states, 'All control blades, including the regulating blade, shall be verified operable within a shift.' During this shiftily verification of control blade operability, all blades were initially verified operable. However, when banking the control blades to their final position after all blades were satisfactorily tested a few seconds earlier, shim control blade 'A' would not move in the inward direction. The LSRO then immediately shut down the reactor by initiating a manual scram by placing the Master Control Switch 1S1 to the 'TEST' position. The LSRO completed all immediate and subsequent actions of reactor emergency procedure REP-2, 'Reactor Scram,' and verified all shim control blades were fully inserted. </br>The inability to manually insert shim control blade 'A' with Control Rod Operate Switch 1S4, which inserts and withdraws the control blade, is a deviation from TS 3.2.a, which states, 'All control blades, including the regulating blade, shall be operable during reactor operation.' </br>Troubleshooting revealed a problem with an electrical contact on Control Rod Operate Switch 1S4, and it has since been replaced. The reactor has not returned to operation at the time of this email. However, permission from the Reactor Facility Director has been obtained to restart the reactor once scheduled maintenance activities have been completed. A detailed event report will follow within 14 days as required by MURR TS 6.6.c(3).n 14 days as required by MURR TS 6.6.c(3).  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 28 January 2019  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
12:30:25, 1 January 2020  +
15:01:00, 28 January 2019  +
Processing error"Processing error" is a predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> and represents errors that appeared in connection with improper value annotations or input processing.
0.575 d (13.8 hours, 0.0821 weeks, 0.0189 months)  +
01:13:00, 28 January 2019  +
Control Blade Inoperable  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.