Browse wiki

Jump to navigation Jump to search
100  +
This report is being made pursuant to 10 CThis report is being made pursuant to 10 CFR 50.72(b)(3)(v)(D), 'any event or condition that at the time of discovery could have prevented the fulfillment of the safety function of structures or systems that are needed to mitigate the consequences of an accident.'</br>At time 2115 CDT on June 19, 2017, one torus to drywell vacuum breaker failed to indicate that it was closed after being cycled for surveillance testing. The vacuum breaker had been cycled open and then closed to satisfy SR 3.6.1.8.2 - Perform a functional test of each required vacuum breaker. Failure of the vacuum breaker to indicate closed after the control switch was taken to the closed position represents a failure to satisfy SR 3.6.1.8.2 and SR 3.6.1.8.1 - Verify each vacuum breaker is closed. Primary containment is allowed to have a bypass area between the drywell and suppression chamber less than or equivalent to a one inch diameter hole. The are of bypass was indeterminate while the vacuum breaker did not indicate fully closed. Primary containment was declared inoperable during the time the vacuum breaker did not indicate fully closed.</br>The vacuum breaker control switch was subsequently cycled open and closed one additional time. At time 2311 CDT, the vacuum breaker indicated fully closed. At that time, primary containment was declared operable.</br>Currently, all twelve Drywell to Suppression Chamber vacuum relief valves are closed and in the normal line-up.</br>The NRC Senior Resident Inspector has been notified.nior Resident Inspector has been notified.  +
02:15:00, 20 June 2017  +
52,813  +
03:31:00, 20 June 2017  +
02:15:00, 20 June 2017  +
This report is being made pursuant to 10 CThis report is being made pursuant to 10 CFR 50.72(b)(3)(v)(D), 'any event or condition that at the time of discovery could have prevented the fulfillment of the safety function of structures or systems that are needed to mitigate the consequences of an accident.'</br>At time 2115 CDT on June 19, 2017, one torus to drywell vacuum breaker failed to indicate that it was closed after being cycled for surveillance testing. The vacuum breaker had been cycled open and then closed to satisfy SR 3.6.1.8.2 - Perform a functional test of each required vacuum breaker. Failure of the vacuum breaker to indicate closed after the control switch was taken to the closed position represents a failure to satisfy SR 3.6.1.8.2 and SR 3.6.1.8.1 - Verify each vacuum breaker is closed. Primary containment is allowed to have a bypass area between the drywell and suppression chamber less than or equivalent to a one inch diameter hole. The are of bypass was indeterminate while the vacuum breaker did not indicate fully closed. Primary containment was declared inoperable during the time the vacuum breaker did not indicate fully closed.</br>The vacuum breaker control switch was subsequently cycled open and closed one additional time. At time 2311 CDT, the vacuum breaker indicated fully closed. At that time, primary containment was declared operable.</br>Currently, all twelve Drywell to Suppression Chamber vacuum relief valves are closed and in the normal line-up.</br>The NRC Senior Resident Inspector has been notified.nior Resident Inspector has been notified.  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
100  +
00:00:00, 20 June 2017  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
01:42:27, 2 March 2018  +
03:31:00, 20 June 2017  +
false  +
0.0529 d (1.27 hours, 0.00756 weeks, 0.00174 months)  +
02:15:00, 20 June 2017  +
Primary Containment Declared Inoperable Due to Failure of Drywell to Suppression Chamber Vacuum Breaker to Fully Close  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.
1  +