The following report was received from the … The following report was received from the Wisconsin Department of Health Services via email:</br>On March 22, 2017, the (Wisconsin Department of Health Services) received a telephone call and email from the licensee's medical physicist that a medical event occurred on December 9, 2016, involving a permanent implant of I-125 seeds for a prostate manual brachytherapy procedure where the total dose delivered differs from the prescribed dose by 20% or more. This is a medical event as described in DHS 157.72(1)(a)1.a. The prescribed dose was 145 Gy; the dose delivered was 114 Gy. The licensee uses D90 (dose delivered to 90% of the clinical target volume) less than 80% for determining medical events. Using the licensee's dose based criteria; the dose received by the prostate was 78% of the intended dose. The underdose was identified during the post-implant computed tomography scan on January 9, 2017 and subsequent dosimetric analysis on January 27, 2017. The licensee's radiation oncologist informed the physicist that supplemental radiation will not be administered and that it is a reportable event on March 22, 2017. Corrective actions are being reviewed by the licensee's staff. DHS (Department of Health Services) inspectors will investigate this medical event.</br>Wisconsin Event ID No.: WI-170005</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.necessarily result in harm to the patient. +
05:00:00, 9 December 2016 +
52,629 +
17:18:00, 22 March 2017 +
05:00:00, 9 December 2016 +
The following report was received from the … The following report was received from the Wisconsin Department of Health Services via email:</br>On March 22, 2017, the (Wisconsin Department of Health Services) received a telephone call and email from the licensee's medical physicist that a medical event occurred on December 9, 2016, involving a permanent implant of I-125 seeds for a prostate manual brachytherapy procedure where the total dose delivered differs from the prescribed dose by 20% or more. This is a medical event as described in DHS 157.72(1)(a)1.a. The prescribed dose was 145 Gy; the dose delivered was 114 Gy. The licensee uses D90 (dose delivered to 90% of the clinical target volume) less than 80% for determining medical events. Using the licensee's dose based criteria; the dose received by the prostate was 78% of the intended dose. The underdose was identified during the post-implant computed tomography scan on January 9, 2017 and subsequent dosimetric analysis on January 27, 2017. The licensee's radiation oncologist informed the physicist that supplemental radiation will not be administered and that it is a reportable event on March 22, 2017. Corrective actions are being reviewed by the licensee's staff. DHS (Department of Health Services) inspectors will investigate this medical event.</br>Wisconsin Event ID No.: WI-170005</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.necessarily result in harm to the patient. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 22 March 2017 +
073-1342-01 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
01:43:02, 2 March 2018 +
17:18:00, 22 March 2017 +
103.554 d (2,485.3 hours, 14.793 weeks, 3.404 months) +
05:00:00, 9 December 2016 +
Brachytherapy + and Underdose +