Browse wiki

Jump to navigation Jump to search
The following information was received froThe following information was received from the State of Georgia via email:</br>Valmet was recently notified by one of their customers (WestRock MWV, LLC, Evadale, TX) regarding a leaking Kr-85 source in one of their general licensed (GL) devices that Valmet had supplied them a year or so ago. (Valmet personnel) retrieved the source and found that it was a slow leaker, and that it needed to be returned to the manufacturer. Valmet exchanged the source in the device and brought the faulty source back to Valmet's office to be returned to the manufacturer. The mill began to suspect a leaking source because of the operating parameters of the equipment. Valmet believes there were no exposures or ingestions of radioactive material, and will have the source returned to the manufacturer soon after the holidays when people are back to work. We expect them to let (the Georgia Radioactive Materials Program) know what the cause of the leak might be.</br>Facility where event occurred: WestRock MWV, LLC, 1913 FM 105, Evadale, TX 77615 - PM4 reel</br>Service Company: Valmet, Inc. 242225 Commerce Ave., Suite 100, Duluth, GA 30096</br>Source manufacturer: QSA Global, GL Device SS&D NR-0596-D-113-G Serial # 50048138, current activity 380 mCi of Kr-85 # 50048138, current activity 380 mCi of Kr-85  +
05:00:00, 16 November 2016  +
52,464  +
07:55:00, 29 December 2016  +
05:00:00, 16 November 2016  +
The following information was received froThe following information was received from the State of Georgia via email:</br>Valmet was recently notified by one of their customers (WestRock MWV, LLC, Evadale, TX) regarding a leaking Kr-85 source in one of their general licensed (GL) devices that Valmet had supplied them a year or so ago. (Valmet personnel) retrieved the source and found that it was a slow leaker, and that it needed to be returned to the manufacturer. Valmet exchanged the source in the device and brought the faulty source back to Valmet's office to be returned to the manufacturer. The mill began to suspect a leaking source because of the operating parameters of the equipment. Valmet believes there were no exposures or ingestions of radioactive material, and will have the source returned to the manufacturer soon after the holidays when people are back to work. We expect them to let (the Georgia Radioactive Materials Program) know what the cause of the leak might be.</br>Facility where event occurred: WestRock MWV, LLC, 1913 FM 105, Evadale, TX 77615 - PM4 reel</br>Service Company: Valmet, Inc. 242225 Commerce Ave., Suite 100, Duluth, GA 30096</br>Source manufacturer: QSA Global, GL Device SS&D NR-0596-D-113-G Serial # 50048138, current activity 380 mCi of Kr-85 # 50048138, current activity 380 mCi of Kr-85  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 29 December 2016  +
GA 458-3  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
22:50:57, 24 November 2018  +
07:55:00, 29 December 2016  +
43.122 d (1,034.92 hours, 6.16 weeks, 1.418 months)  +
05:00:00, 16 November 2016  +
Agreement State - Leaking General Licensed Kr-85 Source  +