The following was excerpted from informatiThe following was excerpted from information received from the Texas Department of State Health Services by email:</br>On November 17, 2016, the licensee notified the Agency (Texas Department of State Health Services) that on November 16, 2016 at approximately 1400 CST, during its semi-annual fixed nuclear gauge inspection (at Chocolate Bayou Works), it had discovered that the shutter mechanism on an Ohmart Model SHLM-BR-2, which contains a 1,000 millicurie cesium-137 source (SN: 2807CG), had become inoperable. The licensee's radiation safety officer reported the source could be moved up/down inside the source tube, but it could not be retracted into the housing. He suspects there is an issue with the positioning of the pin that holds the 2-piece source rod together. Repairs are scheduled to be completed during an operations shut-down in January/February 2017. The source is in its normal operating position and there is no risk of exposure to any individual due to its location.</br>Texas Incident #: I-9441 to its location. Texas Incident #: I-9441  +
20:00:00, 16 November 2016  +
52,373  +
14:07:00, 17 November 2016  +
20:00:00, 16 November 2016  +
The following was excerpted from informatiThe following was excerpted from information received from the Texas Department of State Health Services by email:</br>On November 17, 2016, the licensee notified the Agency (Texas Department of State Health Services) that on November 16, 2016 at approximately 1400 CST, during its semi-annual fixed nuclear gauge inspection (at Chocolate Bayou Works), it had discovered that the shutter mechanism on an Ohmart Model SHLM-BR-2, which contains a 1,000 millicurie cesium-137 source (SN: 2807CG), had become inoperable. The licensee's radiation safety officer reported the source could be moved up/down inside the source tube, but it could not be retracted into the housing. He suspects there is an issue with the positioning of the pin that holds the 2-piece source rod together. Repairs are scheduled to be completed during an operations shut-down in January/February 2017. The source is in its normal operating position and there is no risk of exposure to any individual due to its location.</br>Texas Incident #: I-9441 to its location. Texas Incident #: I-9441  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 17 November 2016  +
L01422  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
01:43:43, 2 March 2018  +
14:07:00, 17 November 2016  +
0.755 d (18.12 hours, 0.108 weeks, 0.0248 months)  +
20:00:00, 16 November 2016  +
Agreement State Report - Stuck Shutter on Fixed Nuclear Gauge  +