The following report was received from theThe following report was received from the Texas Department of State Health Services via email:</br>On October 27, 2016, the Agency (Texas Department of State Health Services) was notified by the licensee's radiation safety officer (RSO) that the shutter on a Berthold model LB7440-D-CR gauge containing a 10 millicurie (original activity) cesium - 137 source would not close. The RSO stated they verified the shutter not closing by performing dose rate surveys around the gauge as they can not see the shutter. The shutter is in the open position which is the normal operating position for the gauge. The RSO stated the gauge does not create an exposure risk to their employees or any member of the general public. The RSO stated a service provider has been contacted to repair the gauge. Additional information will be provided in accordance with SA-300.</br>Texas Incident #: I - 9435ce with SA-300. Texas Incident #: I - 9435  +
05:00:00, 27 October 2016  +
52,326  +
10:55:00, 28 October 2016  +
05:00:00, 27 October 2016  +
The following report was received from theThe following report was received from the Texas Department of State Health Services via email:</br>On October 27, 2016, the Agency (Texas Department of State Health Services) was notified by the licensee's radiation safety officer (RSO) that the shutter on a Berthold model LB7440-D-CR gauge containing a 10 millicurie (original activity) cesium - 137 source would not close. The RSO stated they verified the shutter not closing by performing dose rate surveys around the gauge as they can not see the shutter. The shutter is in the open position which is the normal operating position for the gauge. The RSO stated the gauge does not create an exposure risk to their employees or any member of the general public. The RSO stated a service provider has been contacted to repair the gauge. Additional information will be provided in accordance with SA-300.</br>Texas Incident #: I - 9435ce with SA-300. Texas Incident #: I - 9435  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 28 October 2016  +
01686  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
01:43:53, 2 March 2018  +
10:55:00, 28 October 2016  +
1.247 d (29.92 hours, 0.178 weeks, 0.041 months)  +
05:00:00, 27 October 2016  +
Agreement State Report - Shutter on Gauge Would Not Close  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.