At 1338 CDT, a spurious electrical fault o … At 1338 CDT, a spurious electrical fault on a unit substation motor control center caused a spurious feedwater isolation and required a manual reactor trip on Unit 2 Byron Station due to lowering steam generator level. Auxiliary feedwater automatically actuated to supply feedwater flow and is maintaining steam generator level within procedurally required levels.</br>The motor control center fault resulted in feedwater isolations on two of four steam generators. All rods inserted during the trip. Decay heat is being removed via the steam dumps to condenser. Plant response to the trip was uncomplicated. Unit 2 is in a normal shutdown electrical lineup with power available from offsite. The grid is stable. Byron Station Unit 1 is at 95% power and stable and was unaffected by the transient on Unit 2. The cause of the motor control center fault is under investigation.</br>The licensee has notified the NRC Resident Inspector and will be issuing a press release concerning the manual reactor trip.elease concerning the manual reactor trip. +
18:38:00, 12 October 2016 +
52,295 +
15:17:00, 12 October 2016 +
18:38:00, 12 October 2016 +
At 1338 CDT, a spurious electrical fault o … At 1338 CDT, a spurious electrical fault on a unit substation motor control center caused a spurious feedwater isolation and required a manual reactor trip on Unit 2 Byron Station due to lowering steam generator level. Auxiliary feedwater automatically actuated to supply feedwater flow and is maintaining steam generator level within procedurally required levels.</br>The motor control center fault resulted in feedwater isolations on two of four steam generators. All rods inserted during the trip. Decay heat is being removed via the steam dumps to condenser. Plant response to the trip was uncomplicated. Unit 2 is in a normal shutdown electrical lineup with power available from offsite. The grid is stable. Byron Station Unit 1 is at 95% power and stable and was unaffected by the transient on Unit 2. The cause of the motor control center fault is under investigation.</br>The licensee has notified the NRC Resident Inspector and will be issuing a press release concerning the manual reactor trip.elease concerning the manual reactor trip. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
90 +
00:00:00, 12 October 2016 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
01:44:02, 2 March 2018 +
15:17:00, 12 October 2016 +
true +
true +
-0.14 d (-3.35 hours, -0.0199 weeks, -0.00459 months) +
18:38:00, 12 October 2016 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.