The following was received from the CommonThe following was received from the Commonwealth of Pennsylvania via email:</br>On August 10, 2016, the Department (Pennsylvania Bureau of Radiation Protection) was notified by Testing Services, Inc. that a moisture/density gauge had been damaged while on location at a temporary job site. It is reportable per 10 CFR 30.50(b)(2).</br>While at a temporary job site, a Humboldt Model 5001 gauge was damaged and became unusable after being run over by a compactor. A survey of the gauge indicated that the source was still in its shielded position. A leak test sample has been taken and sent for analysis and the gauge has been removed from service and secured. No over exposures have occurred. A service provider has been contacted to see if repairs are possible or if the gauge will be returned to the manufacturer.</br>Radionuclides: Cs-137 and Am-241:Be</br>Manufacturer: Humboldt</br>Model: 5001</br>Serial Number: 2394</br>Activity: 11 mCi Cs-137, 44 mCi Am-241:Be</br>The gauge has been securely stored and placed out of service until repairs/return can be accomplished. The Department has scheduled a reactive inspection. More information will be provided when available.</br>PA report # PA160022vided when available. PA report # PA160022  +
04:00:00, 8 August 2016  +
52,165  +
11:28:00, 10 August 2016  +
04:00:00, 8 August 2016  +
The following was received from the CommonThe following was received from the Commonwealth of Pennsylvania via email:</br>On August 10, 2016, the Department (Pennsylvania Bureau of Radiation Protection) was notified by Testing Services, Inc. that a moisture/density gauge had been damaged while on location at a temporary job site. It is reportable per 10 CFR 30.50(b)(2).</br>While at a temporary job site, a Humboldt Model 5001 gauge was damaged and became unusable after being run over by a compactor. A survey of the gauge indicated that the source was still in its shielded position. A leak test sample has been taken and sent for analysis and the gauge has been removed from service and secured. No over exposures have occurred. A service provider has been contacted to see if repairs are possible or if the gauge will be returned to the manufacturer.</br>Radionuclides: Cs-137 and Am-241:Be</br>Manufacturer: Humboldt</br>Model: 5001</br>Serial Number: 2394</br>Activity: 11 mCi Cs-137, 44 mCi Am-241:Be</br>The gauge has been securely stored and placed out of service until repairs/return can be accomplished. The Department has scheduled a reactive inspection. More information will be provided when available.</br>PA report # PA160022vided when available. PA report # PA160022  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 10 August 2016  +
PA-1257  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
22:53:42, 24 November 2018  +
11:28:00, 10 August 2016  +
2.311 d (55.47 hours, 0.33 weeks, 0.076 months)  +
04:00:00, 8 August 2016  +
Agreement State Report - Damaged Moisture Density Gauge  +