The following report was received from the … The following report was received from the State of Louisiana via email:</br>The RSO and crew were performing routine maintenance and leak test on industrial radiography equipment on 12/11/2015. The leak test wipes were delivered to their service company NDT Repair (LA-6631-L01) for analysis on 12/14/2015. On 12/17/2015, the RSO received a call from NDT Repair to inform him one of the leak tests came back with slightly elevated results of 0.006 microCi Ir-192. Acceptable limit is 0.005 microCi.</br>The source is being transferred for disposal to SPEC (Source Production & Equipment Company), LA-2966-L01, Mfg. & Service Company in St. Rose, LA (New Orleans, LA). Also, the exposure device and associated equipment are being evaluated for breakthrough and removable contamination before re-sourcing and putting them back into service.</br> </br>Exposure Device SPEC 150, s/n 991 and the 'leaking source' a SPEC Model G-60, s/n WD 2405 with approximately 19 Ci Ir-192.</br>State Event Report ID No.: LA 1500229 Ci Ir-192.
State Event Report ID No.: LA 150022 +
21:15:00, 17 December 2015 +
51,610 +
13:23:00, 18 December 2015 +
21:15:00, 17 December 2015 +
The following report was received from the … The following report was received from the State of Louisiana via email:</br>The RSO and crew were performing routine maintenance and leak test on industrial radiography equipment on 12/11/2015. The leak test wipes were delivered to their service company NDT Repair (LA-6631-L01) for analysis on 12/14/2015. On 12/17/2015, the RSO received a call from NDT Repair to inform him one of the leak tests came back with slightly elevated results of 0.006 microCi Ir-192. Acceptable limit is 0.005 microCi.</br>The source is being transferred for disposal to SPEC (Source Production & Equipment Company), LA-2966-L01, Mfg. & Service Company in St. Rose, LA (New Orleans, LA). Also, the exposure device and associated equipment are being evaluated for breakthrough and removable contamination before re-sourcing and putting them back into service.</br> </br>Exposure Device SPEC 150, s/n 991 and the 'leaking source' a SPEC Model G-60, s/n WD 2405 with approximately 19 Ci Ir-192.</br>State Event Report ID No.: LA 1500229 Ci Ir-192.
State Event Report ID No.: LA 150022 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 18 December 2015 +
LA-7396-L01 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
23:03:42, 24 November 2018 +
13:23:00, 18 December 2015 +
0.672 d (16.13 hours, 0.096 weeks, 0.0221 months) +
21:15:00, 17 December 2015 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.