Browse wiki

Jump to navigation Jump to search
100  +
This is a non-emergency eight hour notificThis is a non-emergency eight hour notification for a loss of Emergency Assessment Capability. This event is reportable in accordance with 10 CFR 50.72(b)(3)(xiii) as the discovered condition affects the functionality of an emergency response facility.</br>A condition impacting functionality of the TSC Ventilation system was discovered on July 7, 2015 at 11:05 EDT. The issue involved a loss of cooling capability of the TSC Ventilation system due to failed ventilation system components. Maintenance started repairs immediately following the discovery of the component failures and completed repairs to restore functionality of the TSC Ventilation system on July 8, 2015 at 17:07 EDT. On July 8, 2015, at approximately 15:30 EDT, further review of the impact of this equipment failure determined that this condition was reportable as a loss of emergency assessment capability.</br>If an emergency were declared requiring TSC activation during the non-functional period, the TSC would have been staffed and activated using existing emergency planning procedures unless the TSC became uninhabitable due to ambient temperature, radiological, or other conditions. If relocation of the TSC became necessary, the Emergency Director would have relocated the TSC staff to an alternate location in accordance with applicable site procedures. The Emergency Response Organization team was notified of the maintenance and the possible need to relocate during an emergency. This condition did not affect the health and safety of the public or station employees. The NRC Resident Inspector has been notified.</br>* * * UPDATE ON 8/27/15 AT 1445 EDT FROM INGRID NORDBY AND JOHN CAVES TO HOWIE CROUCH * * *</br>An extent of condition review revealed three additional instances of loss of cooling capability of the Technical Support Center due to failed ventilation system components: January 7, 2015; June 20, 2015; and June 30, 2015. Functionality was restored after these conditions were identified. Each of these instances was determined to be reportable in accordance with 10 CFR 50.72(b)(3)(xiii). The NRC Resident Inspectors have been notified.</br>Notified R2DO (Rose). have been notified. Notified R2DO (Rose).  
15:05:00, 7 July 2015  +
51,212  +
17:43:00, 8 July 2015  +
15:05:00, 7 July 2015  +
This is a non-emergency eight hour notificThis is a non-emergency eight hour notification for a loss of Emergency Assessment Capability. This event is reportable in accordance with 10 CFR 50.72(b)(3)(xiii) as the discovered condition affects the functionality of an emergency response facility.</br>A condition impacting functionality of the TSC Ventilation system was discovered on July 7, 2015 at 11:05 EDT. The issue involved a loss of cooling capability of the TSC Ventilation system due to failed ventilation system components. Maintenance started repairs immediately following the discovery of the component failures and completed repairs to restore functionality of the TSC Ventilation system on July 8, 2015 at 17:07 EDT. On July 8, 2015, at approximately 15:30 EDT, further review of the impact of this equipment failure determined that this condition was reportable as a loss of emergency assessment capability.</br>If an emergency were declared requiring TSC activation during the non-functional period, the TSC would have been staffed and activated using existing emergency planning procedures unless the TSC became uninhabitable due to ambient temperature, radiological, or other conditions. If relocation of the TSC became necessary, the Emergency Director would have relocated the TSC staff to an alternate location in accordance with applicable site procedures. The Emergency Response Organization team was notified of the maintenance and the possible need to relocate during an emergency. This condition did not affect the health and safety of the public or station employees. The NRC Resident Inspector has been notified.</br>* * * UPDATE ON 8/27/15 AT 1445 EDT FROM INGRID NORDBY AND JOHN CAVES TO HOWIE CROUCH * * *</br>An extent of condition review revealed three additional instances of loss of cooling capability of the Technical Support Center due to failed ventilation system components: January 7, 2015; June 20, 2015; and June 30, 2015. Functionality was restored after these conditions were identified. Each of these instances was determined to be reportable in accordance with 10 CFR 50.72(b)(3)(xiii). The NRC Resident Inspectors have been notified.</br>Notified R2DO (Rose). have been notified. Notified R2DO (Rose).  
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
100  +
00:00:00, 27 August 2015  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
01:46:53, 2 March 2018  +
17:43:00, 8 July 2015  +
false  +
1.11 d (26.63 hours, 0.159 weeks, 0.0365 months)  +
15:05:00, 7 July 2015  +
Technical Support Center Ventilation Out of Service  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.
1  +