Browse wiki
Jump to navigation
Jump to search
At 1105 PST, plant personnel identified th … At 1105 PST, plant personnel identified through-wall seepage in a Diablo Canyon Power Plant Unit 1 socket weld inside containment that provides a flow path to a relief valve protecting a common portion of both trains of the Residual Heat Removal (RHR) System. The as-found condition falls under the requirements of the ASME acceptance criteria. Unit 1 was already in Mode 3, or offline, due to a planned maintenance outage. PG&E accordingly declared both Unit 1 trains of RHR inoperable and has initiated a transition from Mode 3 to Mode 4 in accordance with requirements of Technical Specification 3.0.3. </br>The licensee notified the NRC Resident Inspector. licensee notified the NRC Resident Inspector. +
18:05:00, 31 December 2014 +
20:44:00, 31 December 2014 +
18:05:00, 31 December 2014 +
At 1105 PST, plant personnel identified th … At 1105 PST, plant personnel identified through-wall seepage in a Diablo Canyon Power Plant Unit 1 socket weld inside containment that provides a flow path to a relief valve protecting a common portion of both trains of the Residual Heat Removal (RHR) System. The as-found condition falls under the requirements of the ASME acceptance criteria. Unit 1 was already in Mode 3, or offline, due to a planned maintenance outage. PG&E accordingly declared both Unit 1 trains of RHR inoperable and has initiated a transition from Mode 3 to Mode 4 in accordance with requirements of Technical Specification 3.0.3. </br>The licensee notified the NRC Resident Inspector. licensee notified the NRC Resident Inspector. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
Both Trains of Residual Heat Removal Inoperable Due to Circumferential Crack on a Socket Weld +, Regarding Both Trains of Residual Heat Removal Inoperable Due to Circumferential Crack on a Socket Weld + and 05000275/LER-2015-001, Regarding Both Trains of Residual Heat Removal Inoperable Due to Circumferential Crack on a Socket Weld +
00:00:00, 31 December 2014 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
22:18:36, 24 September 2017 +
20:44:00, 31 December 2014 +
false +
false +
0.11 d (2.65 hours, 0.0158 weeks, 0.00363 months) +
18:05:00, 31 December 2014 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.