Browse wiki

Jump to navigation Jump to search
The following information was received viaThe following information was received via email from the State of California:</br>The current corporate RSO (will also to be assigned as the future RSO for this license) contacted RHB (California Radiologic Health Branch) to report incident that happened on 08/30/13. The RSO was conducting an audit of the program and learned that one of their gauges (Troxler model 3411, S/N 4089, containing 9 mCi of Cs-137 and 44 mCi of Am-241 was run over by a compactor at the Lower Butte Creek Levee Project on 08/30/13. The field technician had reported the incident to the RSO (at the time of the incident). The rod was broken, however, the source was contained within the shielded part of the gauge assembly. The technician brought the damaged gauge back to the licensee's storage facility and it was stored there until it was picked up by PNT on July 24, 2014. The RSO failed to inform the incident to RHB within 24 hrs. and the incident was reported to RHB almost a year later. The licensee is in the process of changing the RSO to the corporate RSO. Recently, the new RSO has provided refresher training to all the gauge users. The facility will be cited for failure to report the incident per CCR 30295 (b) and 10 CFR 30.50 (b) and for failure to follow procedures.</br>CA Report No: 072414o follow procedures. CA Report No: 072414  +
07:00:00, 30 August 2013  +
50,340  +
14:49:00, 4 August 2014  +
07:00:00, 30 August 2013  +
The following information was received viaThe following information was received via email from the State of California:</br>The current corporate RSO (will also to be assigned as the future RSO for this license) contacted RHB (California Radiologic Health Branch) to report incident that happened on 08/30/13. The RSO was conducting an audit of the program and learned that one of their gauges (Troxler model 3411, S/N 4089, containing 9 mCi of Cs-137 and 44 mCi of Am-241 was run over by a compactor at the Lower Butte Creek Levee Project on 08/30/13. The field technician had reported the incident to the RSO (at the time of the incident). The rod was broken, however, the source was contained within the shielded part of the gauge assembly. The technician brought the damaged gauge back to the licensee's storage facility and it was stored there until it was picked up by PNT on July 24, 2014. The RSO failed to inform the incident to RHB within 24 hrs. and the incident was reported to RHB almost a year later. The licensee is in the process of changing the RSO to the corporate RSO. Recently, the new RSO has provided refresher training to all the gauge users. The facility will be cited for failure to report the incident per CCR 30295 (b) and 10 CFR 30.50 (b) and for failure to follow procedures.</br>CA Report No: 072414o follow procedures. CA Report No: 072414  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
Am-241 +  and Cs-137 +
00:00:00, 4 August 2014  +
CA 5927-34  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
23:08:09, 24 November 2018  +
14:49:00, 4 August 2014  +
339.326 d (8,143.82 hours, 48.475 weeks, 11.155 months)  +
07:00:00, 30 August 2013  +
Agreement State Report - Damaged Moisture/Density Gauge  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.