Browse wiki
Jump to navigation
Jump to search
The following information was obtained fro … The following information was obtained from the State of Texas via email:</br>On October 30, 2013, the Agency (Texas Department of Health) was notified by the licensee that while conducting routine maintenance checks on a Texas Nuclear model 5196 nuclear gauge containing a 20 milliCurie cesium137 source, the shutter was found stuck in the open position. The licensee lubricated the operating shaft and attempted to close and reopen the shutter. While attempting to reopen the shutter, the operating rod for the shutter broke. The licensee determined the gauge is in the open position, which is the normal operating position for the gauge. The licensee has contacted the gauge manufacturer and will either repair or replace the gauge. No individual received any additional exposure as a result of this event. Additional information will be provided as it is received in accordance with Reporting Material Events SA-300.</br>Texas Incident #: I-9132al Events SA-300.
Texas Incident #: I-9132 +
05:00:00, 29 October 2013 +
15:46:00, 30 October 2013 +
05:00:00, 29 October 2013 +
The following information was obtained fro … The following information was obtained from the State of Texas via email:</br>On October 30, 2013, the Agency (Texas Department of Health) was notified by the licensee that while conducting routine maintenance checks on a Texas Nuclear model 5196 nuclear gauge containing a 20 milliCurie cesium137 source, the shutter was found stuck in the open position. The licensee lubricated the operating shaft and attempted to close and reopen the shutter. While attempting to reopen the shutter, the operating rod for the shutter broke. The licensee determined the gauge is in the open position, which is the normal operating position for the gauge. The licensee has contacted the gauge manufacturer and will either repair or replace the gauge. No individual received any additional exposure as a result of this event. Additional information will be provided as it is received in accordance with Reporting Material Events SA-300.</br>Texas Incident #: I-9132al Events SA-300.
Texas Incident #: I-9132 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 30 October 2013 +
03521 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
01:52:42, 2 March 2018 +
15:46:00, 30 October 2013 +
1.449 d (34.77 hours, 0.207 weeks, 0.0476 months) +
05:00:00, 29 October 2013 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.