On May 16, 2013, at 0256 EDT, while in Mod … On May 16, 2013, at 0256 EDT, while in Mode 3 (subcritical), operators manually opened the reactor trip breakers as directed by procedure. During rod drop testing, demand position and digital rod position indication did not agree within procedural limits. As directed by procedure, operators opened the reactor trip breakers. The cause of the discrepancy is under investigation. The plant responded as expected and all rods inserted as required. The plant remains stable in Mode 3.</br>This condition is reportable pursuant to 10 CFR 50.72(b)(3)(iv).</br>The NRC Senior Resident Inspector has been notified.</br>* * * RETRACTION FROM TODD STRINGFELLOW TO DANIEL MILLS ON 7/10/2013 AT 1418 EDT * * *</br>The purpose of this call is to retract the report made on May 16, 2013, Event Number 49039. Operators manually opened the reactor trip breakers in MODE 3 during hot control rod drop testing as directed by procedure. The condition has been determined to be an invalid actuation of the RPS since boron concentration, and not control rods, were being relied upon for safety function during rod testing. The details of the engineering review will be provided to the NRC Senior Resident Inspector.</br>Notified R1DO (Cook). Resident Inspector.
Notified R1DO (Cook). +
06:56:00, 16 May 2013 +
49,039 +
10:20:00, 16 May 2013 +
06:56:00, 16 May 2013 +
On May 16, 2013, at 0256 EDT, while in Mod … On May 16, 2013, at 0256 EDT, while in Mode 3 (subcritical), operators manually opened the reactor trip breakers as directed by procedure. During rod drop testing, demand position and digital rod position indication did not agree within procedural limits. As directed by procedure, operators opened the reactor trip breakers. The cause of the discrepancy is under investigation. The plant responded as expected and all rods inserted as required. The plant remains stable in Mode 3.</br>This condition is reportable pursuant to 10 CFR 50.72(b)(3)(iv).</br>The NRC Senior Resident Inspector has been notified.</br>* * * RETRACTION FROM TODD STRINGFELLOW TO DANIEL MILLS ON 7/10/2013 AT 1418 EDT * * *</br>The purpose of this call is to retract the report made on May 16, 2013, Event Number 49039. Operators manually opened the reactor trip breakers in MODE 3 during hot control rod drop testing as directed by procedure. The condition has been determined to be an invalid actuation of the RPS since boron concentration, and not control rods, were being relied upon for safety function during rod testing. The details of the engineering review will be provided to the NRC Senior Resident Inspector.</br>Notified R1DO (Cook). Resident Inspector.
Notified R1DO (Cook). +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 10 July 2013 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
22:22:04, 24 September 2017 +
10:20:00, 16 May 2013 +
false +
false +
0.142 d (3.4 hours, 0.0202 weeks, 0.00466 months) +
06:56:00, 16 May 2013 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.