Browse wiki
Jump to navigation
Jump to search
The following information was obtained fro … The following information was obtained from the State of Nevada via email:</br>The patient was to undergo a HIDA (hepatobiliary) scan for abdominal pain (Tc-99m; 5mCi, abdomen), but given syringe for MDP (bone scan) (Tc-99m; 30mCi; bone). A wrong dose of Tc-99m (600% the prescribed dose) was administered to the patient due to human error.</br>Corrective action: Better training in cross-checking and confirming patient identity with prescribed dose information.</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.</br>Item Number: NV130006</br>* * * RETRACTION FROM SNEHA RAVIKUMAR VIA E-MAIL ON 5/16/13 AT 1329 EDT * * * </br>This is with regard to the wrong dose administration that was reported yesterday. (The State of Nevada) heard back from the RSO regarding the Effective Dose Equivalent: </br>What should have been administered was 5 mCi of HIDA (Mebrofenin) = (3E-02) x 5 rem = 0.15 rem.</br>What was administered was 30 mCi of MDP = (2E-02) x 30 rem = 0.60 rem.</br>So, this would not be reportable.</br>Notified R4DO (Walker) and FSME Events Resource via E-mail.lker) and FSME Events Resource via E-mail. +
16:45:00, 14 May 2013 +
49,037 +
16:54:00, 15 May 2013 +
16:45:00, 14 May 2013 +
The following information was obtained fro … The following information was obtained from the State of Nevada via email:</br>The patient was to undergo a HIDA (hepatobiliary) scan for abdominal pain (Tc-99m; 5mCi, abdomen), but given syringe for MDP (bone scan) (Tc-99m; 30mCi; bone). A wrong dose of Tc-99m (600% the prescribed dose) was administered to the patient due to human error.</br>Corrective action: Better training in cross-checking and confirming patient identity with prescribed dose information.</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.</br>Item Number: NV130006</br>* * * RETRACTION FROM SNEHA RAVIKUMAR VIA E-MAIL ON 5/16/13 AT 1329 EDT * * * </br>This is with regard to the wrong dose administration that was reported yesterday. (The State of Nevada) heard back from the RSO regarding the Effective Dose Equivalent: </br>What should have been administered was 5 mCi of HIDA (Mebrofenin) = (3E-02) x 5 rem = 0.15 rem.</br>What was administered was 30 mCi of MDP = (2E-02) x 30 rem = 0.60 rem.</br>So, this would not be reportable.</br>Notified R4DO (Walker) and FSME Events Resource via E-mail.lker) and FSME Events Resource via E-mail. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 16 May 2013 +
16-12-0244-02 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:00:54, 2 March 2018 +
16:54:00, 15 May 2013 +
1.006 d (24.15 hours, 0.144 weeks, 0.0331 months) +
16:45:00, 14 May 2013 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.