Browse wiki

Jump to navigation Jump to search
The following information was received froThe following information was received from the State of Florida via email:</br>Licensee reported a possible medical event on 8 March which was confirmed in a written report received on 22 March. Patient was being treated by Gamma Knife with 8 shots at four sites when the fifth shot was interrupted for a bathroom break. While in the bathroom the patient fell and dislodged the stereotactic frame. The frame was reapplied and treatment plan recalculated. However, the computer did not start the treatment at the correct site resulting in an increase in dose of 22.2% at site 2, 14.8% at site 3 & 15, and 7% at site 4. The doses are well within clinical practice. A conservative dose prescription had been elevated to a moderate prescription. The referring physician and patient have been notified. No medical consequences are expected. The cause is human error. Any further investigation referred to Licensing and Materials. No further action will be taken on this incident by this office.</br>Device: Leksell Perfexion</br>Serial Number: 6130</br>Florida Incident: FL-12-034</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.not necessarily result in harm to the patient.  +
04:00:00, 8 March 2012  +
47,790  +
08:07:00, 30 March 2012  +
04:00:00, 8 March 2012  +
The following information was received froThe following information was received from the State of Florida via email:</br>Licensee reported a possible medical event on 8 March which was confirmed in a written report received on 22 March. Patient was being treated by Gamma Knife with 8 shots at four sites when the fifth shot was interrupted for a bathroom break. While in the bathroom the patient fell and dislodged the stereotactic frame. The frame was reapplied and treatment plan recalculated. However, the computer did not start the treatment at the correct site resulting in an increase in dose of 22.2% at site 2, 14.8% at site 3 & 15, and 7% at site 4. The doses are well within clinical practice. A conservative dose prescription had been elevated to a moderate prescription. The referring physician and patient have been notified. No medical consequences are expected. The cause is human error. Any further investigation referred to Licensing and Materials. No further action will be taken on this incident by this office.</br>Device: Leksell Perfexion</br>Serial Number: 6130</br>Florida Incident: FL-12-034</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.not necessarily result in harm to the patient.  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 30 March 2012  +
2825-2  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
22:25:33, 24 September 2017  +
08:07:00, 30 March 2012  +
22.213 d (533.12 hours, 3.173 weeks, 0.73 months)  +
04:00:00, 8 March 2012  +
Agreement State Report - Gamma Knife Medical Overexposure  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.