While reviewing Valve Body drawing 16B2201 … While reviewing Valve Body drawing 16B2201, it was discovered that an area in the packing bore has the possibility to not meet the minimum wall requirements of ASME B16.34 for a Class 150 valve at the minimum material condition due to a potential stack up of tolerances.</br>Upon discovery of this possible failure to comply, an investigation was performed on all NPS 3-12 Type A11 Class 150 Seismic Plate Valve Bodies and it was determined that this issue was isolated to the NPS 8 Type A11 Class 150 Seismic Plate Valve Body per drawing 16B2201.</br>It is the opinion of Fisher that there is no inherent safety risk associated with this situation. Fisher will be working with the individual plants (Clinton Power Station and Watts Bar) in question to measure the actual dimensions of the bodies to determine if a problem exists and will take appropriate corrective action.</br>Fisher Information Notice: FIN 2012-01n.
Fisher Information Notice: FIN 2012-01 +
06:00:00, 24 February 2012 +
47,706 +
15:21:00, 28 February 2012 +
06:00:00, 24 February 2012 +
While reviewing Valve Body drawing 16B2201 … While reviewing Valve Body drawing 16B2201, it was discovered that an area in the packing bore has the possibility to not meet the minimum wall requirements of ASME B16.34 for a Class 150 valve at the minimum material condition due to a potential stack up of tolerances.</br>Upon discovery of this possible failure to comply, an investigation was performed on all NPS 3-12 Type A11 Class 150 Seismic Plate Valve Bodies and it was determined that this issue was isolated to the NPS 8 Type A11 Class 150 Seismic Plate Valve Body per drawing 16B2201.</br>It is the opinion of Fisher that there is no inherent safety risk associated with this situation. Fisher will be working with the individual plants (Clinton Power Station and Watts Bar) in question to measure the actual dimensions of the bodies to determine if a problem exists and will take appropriate corrective action.</br>Fisher Information Notice: FIN 2012-01n.
Fisher Information Notice: FIN 2012-01 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 28 February 2012 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:04:46, 2 March 2018 +
15:21:00, 28 February 2012 +
4.39 d (105.35 hours, 0.627 weeks, 0.144 months) +
06:00:00, 24 February 2012 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.