Browse wiki
Jump to navigation
Jump to search
The following information was received fro … The following information was received from the State of Ohio by email:</br>Written directive called for Iodine-125 radioactive seed implant of the prostate with 142 seeds, 0.477 mCi each, total activity 67.7 mCi. Transperineal implantation of the needles were attempted on 12/8/10. After placement of four needles (8 sources) in the first (anterior-most) row, it was subsequently noted that patient's pelvic inlet was too narrow for adequate placement of the lateral two columns of seeds after repeated attempts. Authorized User Physician decided to abort procedure at this point. Patient was taken to the recovery room in satisfactory condition. Patient was notified at time of event. Radiation Safety Officer was not notified at time of event.</br>Licensee's RSO discovered event during QMP review on morning of 1/25/11 and notified ODH (Ohio Department of Health) by telephone and e-mail that afternoon. ODH inspector will visit licensee's location on 1/31/11.</br>Given: Radionuclide: I-125; Activity: 3.2 mCi (118.4 MBq); Dose: 81.1 rad (0.811 Gy).</br>Intended: Radionuclide: I-125; Activity: 67.7 mCi (2504.9 MBq); Dose: 14400 rad (144 Gy).</br>The source used was a Brachytherapy sealed source I-125; Model Number STM-1251; Serial Number 2357321SO; Activity .477 Ci (17.649 GBq).</br>Ohio number: OH110001</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.necessarily result in harm to the patient. +
05:00:00, 8 December 2010 +
10:14:00, 26 January 2011 +
05:00:00, 8 December 2010 +
The following information was received fro … The following information was received from the State of Ohio by email:</br>Written directive called for Iodine-125 radioactive seed implant of the prostate with 142 seeds, 0.477 mCi each, total activity 67.7 mCi. Transperineal implantation of the needles were attempted on 12/8/10. After placement of four needles (8 sources) in the first (anterior-most) row, it was subsequently noted that patient's pelvic inlet was too narrow for adequate placement of the lateral two columns of seeds after repeated attempts. Authorized User Physician decided to abort procedure at this point. Patient was taken to the recovery room in satisfactory condition. Patient was notified at time of event. Radiation Safety Officer was not notified at time of event.</br>Licensee's RSO discovered event during QMP review on morning of 1/25/11 and notified ODH (Ohio Department of Health) by telephone and e-mail that afternoon. ODH inspector will visit licensee's location on 1/31/11.</br>Given: Radionuclide: I-125; Activity: 3.2 mCi (118.4 MBq); Dose: 81.1 rad (0.811 Gy).</br>Intended: Radionuclide: I-125; Activity: 67.7 mCi (2504.9 MBq); Dose: 14400 rad (144 Gy).</br>The source used was a Brachytherapy sealed source I-125; Model Number STM-1251; Serial Number 2357321SO; Activity .477 Ci (17.649 GBq).</br>Ohio number: OH110001</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.necessarily result in harm to the patient. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 26 January 2011 +
02110180013 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:07:57, 2 March 2018 +
10:14:00, 26 January 2011 +
49.218 d (1,181.23 hours, 7.031 weeks, 1.618 months) +
05:00:00, 8 December 2010 +
Brachytherapy + and Underdose +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.