Browse wiki

Jump to navigation Jump to search
The following information was received by The following information was received by facsimile:</br>On September 14, 2010, the Department (Wisconsin Department of Health Services) received a facsimile from the licensee's Radiation Safety Officer (RSO) that a medical event occurred on September 9, 2010, involving a permanent implant of I-125 seeds for a prostate manual brachytherapy procedure where the total dose delivered differs from the prescribed dose by 20% or more. This is a medical event as described in DHS 157.72(1)(a)1. The prescribed dose was 145 Gy; the dose delivered was 80 Gy. The licensee uses D80 < 80% as their dose based criteria for determining medical events. Using the licensee's dose based criteria of D80 < 80% the dose received by the prostate was 55% of the intended dose. The underdose was identified during the post-implant planning for the procedure. The RSO indicated that the possible cause was the maximum insertion depth was 0.6 cm below the base of the prostate gland and all needles were implanted distal to the base resulting in the area being 'cold'. Possible corrective actions are under review by the licensee's staff and a one month post-implant CT is planned to determine the impact to the patient.</br>(Department) inspectors will investigate this medical event on September 16, 2010.</br>Wisconsin Event Report: WI100015</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.s not necessarily result in harm to the patient.  +
05:00:00, 9 September 2010  +
46,249  +
12:57:00, 14 September 2010  +
05:00:00, 9 September 2010  +
The following information was received by The following information was received by facsimile:</br>On September 14, 2010, the Department (Wisconsin Department of Health Services) received a facsimile from the licensee's Radiation Safety Officer (RSO) that a medical event occurred on September 9, 2010, involving a permanent implant of I-125 seeds for a prostate manual brachytherapy procedure where the total dose delivered differs from the prescribed dose by 20% or more. This is a medical event as described in DHS 157.72(1)(a)1. The prescribed dose was 145 Gy; the dose delivered was 80 Gy. The licensee uses D80 < 80% as their dose based criteria for determining medical events. Using the licensee's dose based criteria of D80 < 80% the dose received by the prostate was 55% of the intended dose. The underdose was identified during the post-implant planning for the procedure. The RSO indicated that the possible cause was the maximum insertion depth was 0.6 cm below the base of the prostate gland and all needles were implanted distal to the base resulting in the area being 'cold'. Possible corrective actions are under review by the licensee's staff and a one month post-implant CT is planned to determine the impact to the patient.</br>(Department) inspectors will investigate this medical event on September 16, 2010.</br>Wisconsin Event Report: WI100015</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.s not necessarily result in harm to the patient.  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 14 September 2010  +
141-1162-01  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:08:50, 2 March 2018  +
12:57:00, 14 September 2010  +
5.331 d (127.95 hours, 0.762 weeks, 0.175 months)  +
05:00:00, 9 September 2010  +
Agreement State Report - Delivered Dose Is Different from the Prescribed Dose  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.