Unit 2 was in Hot Shutdown (Mode 4) for a … Unit 2 was in Hot Shutdown (Mode 4) for a Refueling Outage. At 0503 (CDT) on April 19, 2010, a valid Lo-Lo Steam Generator level condition occurred during restoration of feedwater system testing. The feedwater test was a planned activity and included isolation of feedwater to the steam generators. During performance of the test, steam generator levels decreased and the Lo-Lo level setpoint was reached on the 2D steam generator. This generated a reactor trip signal and auxiliary feedwater system start signal. Since the Unit was in Hot Shutdown, the reactor trip breakers were already open, and the auxiliary feedwater system was already removed from service when the steam generator water level unintentionally reached the Lo-Lo level setpoint. Additionally, the open steam generator blowdown isolation valves closed as expected at the Lo-Lo steam generator level setpoint. Steam generator level was promptly restored above the Lo-Lo steam generator setpoint. There was no impact on the reactor cooldown that was concurrently in progress as part of the preparation for refueling. Initial screening of the condition determined as not reportable in accordance with 10 CFR 50.72(b)(3)(iv), however, based upon further review it has been determined the condition is reportable.</br>At the time of the event, both trains of shutdown cooling were in service and there were no challenges to offsite power. The licensee was not required to enter any Technical Specification LCO action statements as a result of the event, and the licensee is still investigating the cause of the decrease in steam generator level below the Lo-Lo level setpoint.</br>The licensee has informed the NRC Resident Inspector.e has informed the NRC Resident Inspector. +
10:03:00, 19 April 2010 +
45,867 +
15:17:00, 22 April 2010 +
10:03:00, 19 April 2010 +
Unit 2 was in Hot Shutdown (Mode 4) for a … Unit 2 was in Hot Shutdown (Mode 4) for a Refueling Outage. At 0503 (CDT) on April 19, 2010, a valid Lo-Lo Steam Generator level condition occurred during restoration of feedwater system testing. The feedwater test was a planned activity and included isolation of feedwater to the steam generators. During performance of the test, steam generator levels decreased and the Lo-Lo level setpoint was reached on the 2D steam generator. This generated a reactor trip signal and auxiliary feedwater system start signal. Since the Unit was in Hot Shutdown, the reactor trip breakers were already open, and the auxiliary feedwater system was already removed from service when the steam generator water level unintentionally reached the Lo-Lo level setpoint. Additionally, the open steam generator blowdown isolation valves closed as expected at the Lo-Lo steam generator level setpoint. Steam generator level was promptly restored above the Lo-Lo steam generator setpoint. There was no impact on the reactor cooldown that was concurrently in progress as part of the preparation for refueling. Initial screening of the condition determined as not reportable in accordance with 10 CFR 50.72(b)(3)(iv), however, based upon further review it has been determined the condition is reportable.</br>At the time of the event, both trains of shutdown cooling were in service and there were no challenges to offsite power. The licensee was not required to enter any Technical Specification LCO action statements as a result of the event, and the licensee is still investigating the cause of the decrease in steam generator level below the Lo-Lo level setpoint.</br>The licensee has informed the NRC Resident Inspector.e has informed the NRC Resident Inspector. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 22 April 2010 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:09:50, 2 March 2018 +
15:17:00, 22 April 2010 +
false +
false +
3.218 d (77.23 hours, 0.46 weeks, 0.106 months) +
10:03:00, 19 April 2010 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.