92 +
A planned modification at the James A. Fit … A planned modification at the James A. Fitzpatrick (JAF) Nuclear Power Plant will replace an air conditioning chiller unit located in the old administration building. The electrical isolations necessary to safely perform the modification will require tagging out a booster fan common to the chiller unit and the Technical Support Center (TSC) ventilation system. Therefore, the TSC ventilation system will be rendered non-functional during the course of the work activities. The TSC ventilation is expected to be out of service for approximately 12 hours.</br>If an emergency is declared requiring TSC activation during this period, the TSC will be staffed and activated using existing emergency planning procedures unless the TSC becomes uninhabitable due to ambient temperature, radiological, or other conditions. If relocation of the TSC becomes necessary, the station Emergency Plant Manager will relocate the TSC staff to an alternate TSC location in accordance with applicable site procedures giving first consideration to the Control Room. TSC facility leads have been made aware of this contingency.</br>This notification is being made in accordance with 10CFR50.72(b)(3)(xiii) due to the potential loss of an emergency response facility (ERF). An update will be provided once the TSC ventilation has been restored to normal operation. The NRC Resident Inspector has been notified.</br> * * * UPDATE FROM CHRIS SMOLINSKI TO CHARLES TEAL ON 1857 EDT 4/12/10 * * *</br>Maintenance on the TSC is complete. The TSC has been returned to service.</br>The licensee has informed the NRC Resident Inspector. Notified R1DO (Gray).Resident Inspector. Notified R1DO (Gray). +
09:00:00, 12 April 2010 +
45,832 +
04:49:00, 12 April 2010 +
09:00:00, 12 April 2010 +
A planned modification at the James A. Fit … A planned modification at the James A. Fitzpatrick (JAF) Nuclear Power Plant will replace an air conditioning chiller unit located in the old administration building. The electrical isolations necessary to safely perform the modification will require tagging out a booster fan common to the chiller unit and the Technical Support Center (TSC) ventilation system. Therefore, the TSC ventilation system will be rendered non-functional during the course of the work activities. The TSC ventilation is expected to be out of service for approximately 12 hours.</br>If an emergency is declared requiring TSC activation during this period, the TSC will be staffed and activated using existing emergency planning procedures unless the TSC becomes uninhabitable due to ambient temperature, radiological, or other conditions. If relocation of the TSC becomes necessary, the station Emergency Plant Manager will relocate the TSC staff to an alternate TSC location in accordance with applicable site procedures giving first consideration to the Control Room. TSC facility leads have been made aware of this contingency.</br>This notification is being made in accordance with 10CFR50.72(b)(3)(xiii) due to the potential loss of an emergency response facility (ERF). An update will be provided once the TSC ventilation has been restored to normal operation. The NRC Resident Inspector has been notified.</br> * * * UPDATE FROM CHRIS SMOLINSKI TO CHARLES TEAL ON 1857 EDT 4/12/10 * * *</br>Maintenance on the TSC is complete. The TSC has been returned to service.</br>The licensee has informed the NRC Resident Inspector. Notified R1DO (Gray).Resident Inspector. Notified R1DO (Gray). +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
92 +
00:00:00, 12 April 2010 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
22:30:32, 24 September 2017 +
04:49:00, 12 April 2010 +
true +
false +
-0.174 d (-4.18 hours, -0.0249 weeks, -0.00573 months) +
09:00:00, 12 April 2010 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.