100  +
At 1828 CST, a fire alarm in the AdministrAt 1828 CST, a fire alarm in the Administration Building was reported to the Fort Calhoun Station Control Room. The Administration Building is located outside of the Protected Area on Owner Controlled Property. An Equipment Operator was dispatched to investigate the cause of the alarm. The Control Room entered AOP-06 Fire Emergency at 1830 CST.</br>At 1832 CST, a report was received from a building occupant that smoke was emanating from a Mechanical Equipment Room located on the first floor of the building. At that time, personnel in the building attempted to extinguish the fire using a portable fire extinguisher but were unsuccessful. Local Fire Departments in the City of Blair and Fort Calhoun were dispatched.</br>At 1840 CST, the Operator arrived at the scene, found light smoke coming from the Mechanical Equipment Room and proceeded to de-energize the ventilation equipment. At 1844 CST, the fire was then extinguished using portable fire extinguishers. It was at that time that Blair and Fort Calhoun Fire Companies arrived on site to assist.</br>At 1911 CST, AOP-06 was exited. Preliminary investigation shows that filter media had become dislodged and contacted duct heaters in the ventilation system. The fire ignited secondary material in the area. The Protected Area of Fort Calhoun Station was not affected at any time during this incident.</br>This event may cause heightened public or government concern related to the health and safety of on-site personnel. Therefore, this report is being made in reference to 10 CFR 50.72(b)(2)(xi).</br>The licensee informed the NRC Resident Inspector and plans to issue a press release.pector and plans to issue a press release.  +
00:28:00, 6 February 2009  +
44,833  +
22:25:00, 5 February 2009  +
00:28:00, 6 February 2009  +
At 1828 CST, a fire alarm in the AdministrAt 1828 CST, a fire alarm in the Administration Building was reported to the Fort Calhoun Station Control Room. The Administration Building is located outside of the Protected Area on Owner Controlled Property. An Equipment Operator was dispatched to investigate the cause of the alarm. The Control Room entered AOP-06 Fire Emergency at 1830 CST.</br>At 1832 CST, a report was received from a building occupant that smoke was emanating from a Mechanical Equipment Room located on the first floor of the building. At that time, personnel in the building attempted to extinguish the fire using a portable fire extinguisher but were unsuccessful. Local Fire Departments in the City of Blair and Fort Calhoun were dispatched.</br>At 1840 CST, the Operator arrived at the scene, found light smoke coming from the Mechanical Equipment Room and proceeded to de-energize the ventilation equipment. At 1844 CST, the fire was then extinguished using portable fire extinguishers. It was at that time that Blair and Fort Calhoun Fire Companies arrived on site to assist.</br>At 1911 CST, AOP-06 was exited. Preliminary investigation shows that filter media had become dislodged and contacted duct heaters in the ventilation system. The fire ignited secondary material in the area. The Protected Area of Fort Calhoun Station was not affected at any time during this incident.</br>This event may cause heightened public or government concern related to the health and safety of on-site personnel. Therefore, this report is being made in reference to 10 CFR 50.72(b)(2)(xi).</br>The licensee informed the NRC Resident Inspector and plans to issue a press release.pector and plans to issue a press release.  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
100  +
00:00:00, 5 February 2009  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:12:44, 2 March 2018  +
22:25:00, 5 February 2009  +
false  +
-0.0854 d (-2.05 hours, -0.0122 weeks, -0.00281 months)  +
00:28:00, 6 February 2009  +
Offsite Notification to Local Fire Departments for Assistance  +