The following information was provided by The following information was provided by the State via e-mail:</br>On 01/05/2009, an unlabeled, unmarked package containing 278 mCi of Rubidium-82 for cardiac PET studies was received at (the University of California at San Francisco) UCSF Receiving Department. The package was surveyed with radiation levels of 17 mR/hr at the surface and 0.5 mR/hr at 1 meter. A wipe of the package was negative. The container was not the usual one that UCSF has received for incoming shipments of Rubidium-82. The Receiving Department failed to contact the RSO's office, and instead contacted Nuclear Medicine to take custody of the package. Nuclear Medicine took custody of the package and exchanged the new Rubidium-82 generator for the old one. Nuclear Medicine alerted the RSO on 01/06/09, to the matter. The package insert indicated that the package was distributed by Bracco Diagnostics in Princeton, New Jersey.</br>The UCSF Assistant RSO contacted personnel at Bracco Diagnostics and was subsequently referred to GE Healthcare in South Plainfield, NJ. Personnel at the GE Healthcare facility are investigating the matter and will report back to the assigned State of California inspector.</br>State of California Report No. 1725-5010. State of California Report No. 1725-5010  +
08:00:00, 5 January 2009  +
44,755  +
16:59:00, 6 January 2009  +
08:00:00, 5 January 2009  +
The following information was provided by The following information was provided by the State via e-mail:</br>On 01/05/2009, an unlabeled, unmarked package containing 278 mCi of Rubidium-82 for cardiac PET studies was received at (the University of California at San Francisco) UCSF Receiving Department. The package was surveyed with radiation levels of 17 mR/hr at the surface and 0.5 mR/hr at 1 meter. A wipe of the package was negative. The container was not the usual one that UCSF has received for incoming shipments of Rubidium-82. The Receiving Department failed to contact the RSO's office, and instead contacted Nuclear Medicine to take custody of the package. Nuclear Medicine took custody of the package and exchanged the new Rubidium-82 generator for the old one. Nuclear Medicine alerted the RSO on 01/06/09, to the matter. The package insert indicated that the package was distributed by Bracco Diagnostics in Princeton, New Jersey.</br>The UCSF Assistant RSO contacted personnel at Bracco Diagnostics and was subsequently referred to GE Healthcare in South Plainfield, NJ. Personnel at the GE Healthcare facility are investigating the matter and will report back to the assigned State of California inspector.</br>State of California Report No. 1725-5010. State of California Report No. 1725-5010  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 6 January 2009  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:12:55, 2 March 2018  +
16:59:00, 6 January 2009  +
1.374 d (32.98 hours, 0.196 weeks, 0.0452 months)  +
08:00:00, 5 January 2009  +
Agreement State - Receipt of an Unlabeled Radioactive Material Package  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.