Millstone Unit 1 is in a decommissioning s … Millstone Unit 1 is in a decommissioning status but still maintains spent fuel in the spent fuel pool. On January 30, 2008, the normal power to the Unit 1 spent fuel pool was lost due to a fault (overcurrent trip) in the "Trayer Switch" (an auto disconnect switch) in the electrical supply line to the spent fuel pool cooling bus. A backup diesel generator was started and was being used to power the spent fuel pool cooling system until the "Trayer Switch" was repaired. At approximately 0840 EST today (2/01/08), alarms were received indicating low decay heat pump low flow and low spent fuel pool cooling pump low flow and discharge pressure. Investigation revealed that the backup diesel generator was operating at a frequency of 57.5 Hz rather than the normal 60 Hz. The technical staff was unable to get the diesel generator to maintain the normal 60 Hz output frequency. The licensee elected to secure the spent fuel pool cooling system pumps at 1024 EST based on concerns that the pumps could be damaged if operated at under frequency for an extended period of time.</br>Licensee technicians are currently engaged in repairing the diesel generator frequency controls and estimate that it could be returned to service this afternoon. The licensee has also ordered a temporary skid mounted diesel generator which should also arrive this afternoon. The repairs to the normal power source are not anticipated to be completed until Monday (2/04/08). </br>The spent fuel pool temperature has increased 1 degree to 86 F in approximately 4 hours. The tech spec limit on spent fuel pool temperature is 150 F. The licensee states that other unit electrical systems powered off the diesel, such as lighting and rad monitors, continue to operate normally at the reduced output frequency of the diesel. One security tower has been slightly impacted but appropriate compensatory measures were implemented.</br>A Millstone Unit 2/3 Resident Inspector has been notified. The licensee has attempted to contact the Regional Inspector.tempted to contact the Regional Inspector.
15:24:00, 1 February 2008 +
43,951 +
13:47:00, 1 February 2008 +
15:24:00, 1 February 2008 +
Millstone Unit 1 is in a decommissioning s … Millstone Unit 1 is in a decommissioning status but still maintains spent fuel in the spent fuel pool. On January 30, 2008, the normal power to the Unit 1 spent fuel pool was lost due to a fault (overcurrent trip) in the "Trayer Switch" (an auto disconnect switch) in the electrical supply line to the spent fuel pool cooling bus. A backup diesel generator was started and was being used to power the spent fuel pool cooling system until the "Trayer Switch" was repaired. At approximately 0840 EST today (2/01/08), alarms were received indicating low decay heat pump low flow and low spent fuel pool cooling pump low flow and discharge pressure. Investigation revealed that the backup diesel generator was operating at a frequency of 57.5 Hz rather than the normal 60 Hz. The technical staff was unable to get the diesel generator to maintain the normal 60 Hz output frequency. The licensee elected to secure the spent fuel pool cooling system pumps at 1024 EST based on concerns that the pumps could be damaged if operated at under frequency for an extended period of time.</br>Licensee technicians are currently engaged in repairing the diesel generator frequency controls and estimate that it could be returned to service this afternoon. The licensee has also ordered a temporary skid mounted diesel generator which should also arrive this afternoon. The repairs to the normal power source are not anticipated to be completed until Monday (2/04/08). </br>The spent fuel pool temperature has increased 1 degree to 86 F in approximately 4 hours. The tech spec limit on spent fuel pool temperature is 150 F. The licensee states that other unit electrical systems powered off the diesel, such as lighting and rad monitors, continue to operate normally at the reduced output frequency of the diesel. One security tower has been slightly impacted but appropriate compensatory measures were implemented.</br>A Millstone Unit 2/3 Resident Inspector has been notified. The licensee has attempted to contact the Regional Inspector.tempted to contact the Regional Inspector.
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 1 February 2008 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:15:07, 2 March 2018 +
13:47:00, 1 February 2008 +
false +
false +
-0.0675 d (-1.62 hours, -0.00964 weeks, -0.00222 months) +
15:24:00, 1 February 2008 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.