Browse wiki

Jump to navigation Jump to search
{{#Regex_clear:Information from a Phased A{{#Regex_clear:Information from a Phased Array UT examination of RRF-F002 (Reactor Recirc 'F' Nozzle to Safe-end weld) indicates that a linear indication approximately 7" long (centered at the bottom of the weld) and approximately 30% through wall extent (ID connected) exists. The Phased Array UT examination of RRF-F002 (Reactor Recirc 'F' Nozzle to Safe-end weld) was performed as part of scheduled outage activities.</br>TRM LCO 3.7.3 for Structural Integrity, Condition B has been entered for the Recirc nozzle/piping.</br>This event is reportable under � 50.72(b)(3)(ii), 'Any event or condition that results in: (A) The condition of the nuclear power plant, including its principal safety barriers, being seriously degraded', when there are welding or material defects in the primary coolant system which cannot be found acceptable under ASME Section XI, IWB-3600, 'Analytical Evaluation of Flaws' or ASME Section XI, Table IWB-3410-1, 'Acceptance Standards.'</br>The licensee informed the NRC Resident Inspector.</br>* * * UPDATE PROVIDED BY HANS OLSON TO JEFF ROTTON AT 2315 EST ON 02/21/07 * * *</br>Information from a Phased Array UT examination of RRC-F002 (Reactor Recirc 'C' Nozzle to Safe-end weld) indicates that a linear indication approximately 10" long and approximately 82% through wall extent (Inner Diameter connected) exists. The Phased Array UT examination of RRC-F002 (Reactor Recirc 'C' Nozzle to Safe-end weld) was performed as part of a follow-up activity for an extent of condition evaluation on RRF-F002 (Reactor Recirc 'F' Nozzle to Safe-end weld).</br>TRM LCO 3.7.3 for Structural Integrity, Condition B has been entered for the Recirc nozzle/piping.</br>Corrected error in original report due to event entry error that identified the affected nozzle as RRF-17002 vice the correct identification of RRF-F002</br>The licensee notified the NRC Resident Inspector. Notified R3DO (Burgess) }}ent Inspector. Notified R3DO (Burgess) }}  +
06:00:00, 19 February 2007  +
43,172  +
15:34:00, 19 February 2007  +
06:00:00, 19 February 2007  +
{{#Regex_clear:Information from a Phased A{{#Regex_clear:Information from a Phased Array UT examination of RRF-F002 (Reactor Recirc 'F' Nozzle to Safe-end weld) indicates that a linear indication approximately 7" long (centered at the bottom of the weld) and approximately 30% through wall extent (ID connected) exists. The Phased Array UT examination of RRF-F002 (Reactor Recirc 'F' Nozzle to Safe-end weld) was performed as part of scheduled outage activities.</br>TRM LCO 3.7.3 for Structural Integrity, Condition B has been entered for the Recirc nozzle/piping.</br>This event is reportable under � 50.72(b)(3)(ii), 'Any event or condition that results in: (A) The condition of the nuclear power plant, including its principal safety barriers, being seriously degraded', when there are welding or material defects in the primary coolant system which cannot be found acceptable under ASME Section XI, IWB-3600, 'Analytical Evaluation of Flaws' or ASME Section XI, Table IWB-3410-1, 'Acceptance Standards.'</br>The licensee informed the NRC Resident Inspector.</br>* * * UPDATE PROVIDED BY HANS OLSON TO JEFF ROTTON AT 2315 EST ON 02/21/07 * * *</br>Information from a Phased Array UT examination of RRC-F002 (Reactor Recirc 'C' Nozzle to Safe-end weld) indicates that a linear indication approximately 10" long and approximately 82% through wall extent (Inner Diameter connected) exists. The Phased Array UT examination of RRC-F002 (Reactor Recirc 'C' Nozzle to Safe-end weld) was performed as part of a follow-up activity for an extent of condition evaluation on RRF-F002 (Reactor Recirc 'F' Nozzle to Safe-end weld).</br>TRM LCO 3.7.3 for Structural Integrity, Condition B has been entered for the Recirc nozzle/piping.</br>Corrected error in original report due to event entry error that identified the affected nozzle as RRF-17002 vice the correct identification of RRF-F002</br>The licensee notified the NRC Resident Inspector. Notified R3DO (Burgess) }}ent Inspector. Notified R3DO (Burgess) }}  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 21 February 2007  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:17:11, 2 March 2018  +
15:34:00, 19 February 2007  +
false  +
false  +
0.399 d (9.57 hours, 0.057 weeks, 0.0131 months)  +
06:00:00, 19 February 2007  +
Degraded Condition - 30% Through Wall Indication on Reactor Recirc Nozzle  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.
1  +