Browse wiki
Jump to navigation
Jump to search
Eberhart/United Consultants, Inc. located … Eberhart/United Consultants, Inc. located in Placentia, CA reported to the State of California at 1000 PDT on 05/17/06 that one of their CPN MC3 (serial number M390304918) moisture density gauge was run over at a work site; Fontana Speedway, 9300 Cherry Avenue, CA; at 0830 PDT. When the gauge was run over the gauge was in backscatter mode of operation. The casing of the gauge was destroyed. The area was cordoned off and the RSO for Eberhart/United Consultants, Inc. was contacted. CPN Maurer Technical Services came out to the site and took possession of the gauge and took it back to their facility located in Laguna Hills. Wipe test of the sources are clean and the sources will be leak tested. Maurer Technical Services reported that the shielding for the Cesium-137 source had been compromised. State of California representative stated the highest radiation reading from the gauge at one foot was 18 milliRem per hour. The gauge contains a 10 milliCurie Cesium-137 source and a 50 millicurie Am-241/Be source. The RSO will be giving retraining to all staff to cover the emergency procedures for this type of incident.ency procedures for this type of incident. +
15:30:00, 17 May 2006 +
42,583 +
20:28:00, 17 May 2006 +
15:30:00, 17 May 2006 +
Eberhart/United Consultants, Inc. located … Eberhart/United Consultants, Inc. located in Placentia, CA reported to the State of California at 1000 PDT on 05/17/06 that one of their CPN MC3 (serial number M390304918) moisture density gauge was run over at a work site; Fontana Speedway, 9300 Cherry Avenue, CA; at 0830 PDT. When the gauge was run over the gauge was in backscatter mode of operation. The casing of the gauge was destroyed. The area was cordoned off and the RSO for Eberhart/United Consultants, Inc. was contacted. CPN Maurer Technical Services came out to the site and took possession of the gauge and took it back to their facility located in Laguna Hills. Wipe test of the sources are clean and the sources will be leak tested. Maurer Technical Services reported that the shielding for the Cesium-137 source had been compromised. State of California representative stated the highest radiation reading from the gauge at one foot was 18 milliRem per hour. The gauge contains a 10 milliCurie Cesium-137 source and a 50 millicurie Am-241/Be source. The RSO will be giving retraining to all staff to cover the emergency procedures for this type of incident.ency procedures for this type of incident. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
Cesium-137 + and Am-241/Be +
00:00:00, 17 May 2006 +
CA 3564-30 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
23:35:12, 24 November 2018 +
20:28:00, 17 May 2006 +
0.207 d (4.97 hours, 0.0296 weeks, 0.00681 months) +
15:30:00, 17 May 2006 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.