The State provided the following informatiThe State provided the following information via facsimile:</br>This is a notification of a potential overexposure. (A technician) was repairing a leak on a high pressure line on a cyclotron. While testing the pressure line, the target unload line at the bottom of the target came lose. This resulted in a mist of water containing F-18. This mist contaminated (the technician's) lab coat. The lab coat was removed with the personnel monitoring badge attached and put behind some lead shielding for decay. This occurred on a Friday so the lab coat was (resurveyed on Monday morning) and was not contaminated. (The technician and) the rest of his clothes (were) not contaminated. This is how the facility believes the overexposure of 12 Rem occurred. The facility has put the following in place as corrective action: The technician will share his maintenance work with another qualified operator for the next six months. Chirping personal dosimeters will be worn during high dose maintenance. Instruction will be given concerning the hazards of radioactivity under pressure. All personnel will report any worker contamination to the RSO within 4 hours.</br>LA Event Report ID No.: LA050004 4 hours. LA Event Report ID No.: LA050004  +
05:00:00, 4 February 2005  +
41,672  +
11:53:00, 6 May 2005  +
05:00:00, 4 February 2005  +
The State provided the following informatiThe State provided the following information via facsimile:</br>This is a notification of a potential overexposure. (A technician) was repairing a leak on a high pressure line on a cyclotron. While testing the pressure line, the target unload line at the bottom of the target came lose. This resulted in a mist of water containing F-18. This mist contaminated (the technician's) lab coat. The lab coat was removed with the personnel monitoring badge attached and put behind some lead shielding for decay. This occurred on a Friday so the lab coat was (resurveyed on Monday morning) and was not contaminated. (The technician and) the rest of his clothes (were) not contaminated. This is how the facility believes the overexposure of 12 Rem occurred. The facility has put the following in place as corrective action: The technician will share his maintenance work with another qualified operator for the next six months. Chirping personal dosimeters will be worn during high dose maintenance. Instruction will be given concerning the hazards of radioactivity under pressure. All personnel will report any worker contamination to the RSO within 4 hours.</br>LA Event Report ID No.: LA050004 4 hours. LA Event Report ID No.: LA050004  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
4.62963e-5 d (0.00111 hours, 6.613757e-6 weeks, 1.522e-6 months)  +
00:00:00, 6 May 2005  +
LA-7390-L01  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
23:38:11, 24 November 2018  +
11:53:00, 6 May 2005  +
91.328 d (2,191.88 hours, 13.047 weeks, 3.002 months)  +
05:00:00, 4 February 2005  +
Agreement State - Potential Overexposure  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.