Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000352/LER-1990-003, :on 900208,HPCI Sys Inboard Isolation Valve Isolated During Isolation Logic Surveillance Test.Caused by Mfg Error.Program for Replacement/Rework of Trip Units Being Implemented.Estimated Completion Date Dec 1993 +, 05000352/LER-1990-003, :on 900208,HPCI Sys Inboard Isolation Valve Isolated During Isolation Logic Surveillance Test.Caused by Mfg Error.Program for Replacement/Rework of Trip Units Being Implemented.Estimated Completion Date Dec 1993 +, 05000352/LER-1990-003, :on 900208,HPCI Sys Inboard Isolation Valve Isolated During Isolation Logic Surveillance Test.Caused by Mfg Error.Program for Replacement/Rework of Trip Units Being Implemented.Estimated Completion Date Dec 1993 +, 05000352/LER-1990-003, :on 900208,HPCI Sys Inboard Isolation Valve Isolated During Isolation Logic Surveillance Test.Caused by Mfg Error.Program for Replacement/Rework of Trip Units Being Implemented.Estimated Completion Date Dec 1993 +, 05000352/LER-1990-003, :on 900208,HPCI Sys Inboard Isolation Valve Isolated During Isolation Logic Surveillance Test.Caused by Mfg Error.Program for Replacement/Rework of Trip Units Being Implemented.Estimated Completion Date Dec 1993 +, 05000352/LER-1990-003, :on 900208,HPCI Sys Inboard Isolation Valve Isolated During Isolation Logic Surveillance Test.Caused by Mfg Error.Program for Replacement/Rework of Trip Units Being Implemented.Estimated Completion Date Dec 1993 +, 05000352/LER-1990-003, :on 900208,HPCI Sys Inboard Isolation Valve Isolated During Isolation Logic Surveillance Test.Caused by Mfg Error.Program for Replacement/Rework of Trip Units Being Implemented.Estimated Completion Date Dec 1993 +, 05000352/LER-1990-003, :on 900208,HPCI Sys Inboard Isolation Valve Isolated During Isolation Logic Surveillance Test.Caused by Mfg Error.Program for Replacement/Rework of Trip Units Being Implemented.Estimated Completion Date Dec 1993 +, 05000352/LER-1990-003, :on 900208,HPCI Sys Inboard Isolation Valve Isolated During Isolation Logic Surveillance Test.Caused by Mfg Error.Program for Replacement/Rework of Trip Units Being Implemented.Estimated Completion Date Dec 1993 +, 05000352/LER-1990-003, :on 900208,HPCI Sys Inboard Isolation Valve Isolated During Isolation Logic Surveillance Test.Caused by Mfg Error.Program for Replacement/Rework of Trip Units Being Implemented.Estimated Completion Date Dec 1993 +, 05000352/LER-1990-003, :on 900208,HPCI Sys Inboard Isolation Valve Isolated During Isolation Logic Surveillance Test.Caused by Mfg Error.Program for Replacement/Rework of Trip Units Being Implemented.Estimated Completion Date Dec 1993 +, 05000352/LER-1990-003, :on 900208,HPCI Sys Inboard Isolation Valve Isolated During Isolation Logic Surveillance Test.Caused by Mfg Error.Program for Replacement/Rework of Trip Units Being Implemented.Estimated Completion Date Dec 1993 +, 05000352/LER-1990-003, :on 900208,HPCI Sys Inboard Isolation Valve Isolated During Isolation Logic Surveillance Test.Caused by Mfg Error.Program for Replacement/Rework of Trip Units Being Implemented.Estimated Completion Date Dec 1993 +, 05000352/LER-1990-003, :on 900208,HPCI Sys Inboard Isolation Valve Isolated During Isolation Logic Surveillance Test.Caused by Mfg Error.Program for Replacement/Rework of Trip Units Being Implemented.Estimated Completion Date Dec 1993 +, 05000352/LER-1990-003, :on 900208,HPCI Sys Inboard Isolation Valve Isolated During Isolation Logic Surveillance Test.Caused by Mfg Error.Program for Replacement/Rework of Trip Units Being Implemented.Estimated Completion Date Dec 1993 +  and 05000352/LER-1990-003, :on 900208,HPCI Sys Inboard Isolation Valve Isolated During Isolation Logic Surveillance Test.Caused by Mfg Error.Program for Replacement/Rework of Trip Units Being Implemented.Estimated Completion Date Dec 1993 +
0.0202 d (0.485 hours, 0.00289 weeks, 6.639725e-4 months)  +, 0.0227 d (0.544 hours, 0.00324 weeks, 7.446385e-4 months)  +, 2.314815e-5 d (5.555556e-4 hours, 3.306878e-6 weeks, 7.61e-7 months)  +  and 0.0244 d (0.587 hours, 0.00349 weeks, 8.03616e-4 months)  +
October 1, 1991  +
1,990  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
11:15:38, 26 May 2025  +
October 1, 1991  +
:on 900208,HPCI Sys Inboard Isolation Valve Isolated During Isolation Logic Surveillance Test.Caused by Mfg Error.Program for Replacement/Rework of Trip Units Being Implemented.Estimated Completion Date Dec 1993   +