Browse wiki

Jump to navigation Jump to search
An NRC-identified non-cited violation (NCVAn NRC-identified non-cited violation (NCV) of 10 CFR 50, Appendix B, Criterion III, Design Control, was identified for the licensees failure to evaluate or test the Electro Magnetic Interference/Radio Frequency Interference (EMI/RFI) effects of the Solid State Protection System (SSPS) power supplies to ensure adequacy of design. The licensee initiated a Condition Report (CR) 10078615, EMI/RFI Testing for SSPS Power Supplies, to address this issue. The licensee performed an Immediate Determination of Operability (IDO) and Prompt Determination of Operability (PDO) and determined the power supplies were operable but nonconforming. The performance deficiency was determined to be more than minor because it adversely affected the Mitigating Systems cornerstone objective of ensuring availability, reliability and capability of systems that respond to initiating events to prevent undesirable consequences and was associated with the cornerstone attribute of Design Control. Failure to evaluate or test the EMI/RFI of SSPS components could cause spurious actuations or failure to actuate. The finding was of very low safety significance (Green) because it did not affect the reactor protection systems tripping signal to initiate a reactor scram because it would be limited to a single channel at a time, did not involve control manipulation that added positive reactivity, and did not result in a mismanagement of reactivity by operators. No cross-cutting aspect was assigned to this finding because it was not indicative of current licensee performance.ndicative of current licensee performance.  +
23:59:59, 30 September 2015  +
05000348  +
23:59:59, 30 September 2015  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
12:58:33, 25 September 2017  +
23:59:59, 30 September 2015  +
Failure to Evaluate or Test EMI/RFI Effect for Solid State Protection System Power Supply  +