Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000265/LER-1983-020-01, /01T-0:on 831027,test Data Revealed Six 12 & 28- Inch Welds on Reactor Recirculation Sys & One 20-inch Weld on RHR Shutdown Cooling Had Circumferential Indications. Caused by Intergranular Stress Corrosion +, 05000265/LER-1983-020-01, /01T-0:on 831027,test Data Revealed Six 12 & 28- Inch Welds on Reactor Recirculation Sys & One 20-inch Weld on RHR Shutdown Cooling Had Circumferential Indications. Caused by Intergranular Stress Corrosion +, 05000265/LER-1983-020-01, /01T-0:on 831027,test Data Revealed Six 12 & 28- Inch Welds on Reactor Recirculation Sys & One 20-inch Weld on RHR Shutdown Cooling Had Circumferential Indications. Caused by Intergranular Stress Corrosion +, 05000265/LER-1983-020-01, /01T-0:on 831027,test Data Revealed Six 12 & 28- Inch Welds on Reactor Recirculation Sys & One 20-inch Weld on RHR Shutdown Cooling Had Circumferential Indications. Caused by Intergranular Stress Corrosion +, 05000265/LER-1983-020-01, /01T-0:on 831027,test Data Revealed Six 12 & 28- Inch Welds on Reactor Recirculation Sys & One 20-inch Weld on RHR Shutdown Cooling Had Circumferential Indications. Caused by Intergranular Stress Corrosion +, 05000265/LER-1983-020-01, /01T-0:on 831027,test Data Revealed Six 12 & 28- Inch Welds on Reactor Recirculation Sys & One 20-inch Weld on RHR Shutdown Cooling Had Circumferential Indications. Caused by Intergranular Stress Corrosion +, 05000265/LER-1983-020-01, /01T-0:on 831027,test Data Revealed Six 12 & 28- Inch Welds on Reactor Recirculation Sys & One 20-inch Weld on RHR Shutdown Cooling Had Circumferential Indications. Caused by Intergranular Stress Corrosion +, 05000265/LER-1983-020-01, /01T-0:on 831027,test Data Revealed Six 12 & 28- Inch Welds on Reactor Recirculation Sys & One 20-inch Weld on RHR Shutdown Cooling Had Circumferential Indications. Caused by Intergranular Stress Corrosion +, 05000265/LER-1983-020-01, /01T-0:on 831027,test Data Revealed Six 12 & 28- Inch Welds on Reactor Recirculation Sys & One 20-inch Weld on RHR Shutdown Cooling Had Circumferential Indications. Caused by Intergranular Stress Corrosion +, 05000265/LER-1983-020-01, /01T-0:on 831027,test Data Revealed Six 12 & 28- Inch Welds on Reactor Recirculation Sys & One 20-inch Weld on RHR Shutdown Cooling Had Circumferential Indications. Caused by Intergranular Stress Corrosion +, 05000265/LER-1983-020-01, /01T-0:on 831027,test Data Revealed Six 12 & 28- Inch Welds on Reactor Recirculation Sys & One 20-inch Weld on RHR Shutdown Cooling Had Circumferential Indications. Caused by Intergranular Stress Corrosion +, 05000265/LER-1983-020-01, /01T-0:on 831027,test Data Revealed Six 12 & 28- Inch Welds on Reactor Recirculation Sys & One 20-inch Weld on RHR Shutdown Cooling Had Circumferential Indications. Caused by Intergranular Stress Corrosion +, 05000265/LER-1983-020-01, /01T-0:on 831027,test Data Revealed Six 12 & 28- Inch Welds on Reactor Recirculation Sys & One 20-inch Weld on RHR Shutdown Cooling Had Circumferential Indications. Caused by Intergranular Stress Corrosion + and 05000265/LER-1983-020-01, /01T-0:on 831027,test Data Revealed Six 12 & 28- Inch Welds on Reactor Recirculation Sys & One 20-inch Weld on RHR Shutdown Cooling Had Circumferential Indications. Caused by Intergranular Stress Corrosion +
November 7, 1983 +
20 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
12:27:32, 14 December 2024 +
4 +
November 7, 1983 +
/01T-0:on 831027,test Data Revealed Six 12 & 28- Inch Welds on Reactor Recirculation Sys & One 20-inch Weld on RHR Shutdown Cooling Had Circumferential Indications. Caused by Intergranular Stress Corrosion +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.