Browse wiki

Jump to navigation Jump to search
The inspectors identified a Green finding The inspectors identified a Green finding and an associated NCV of Title 10 of the Code of Federal Regulations(CFR), Part 50, Appendix B, Criterion XI, Test Control, for the failure to assure that applicable requirements and acceptance limits contained in the inboard main steam isolation valve (MSIV) design documents were incorporated into their test procedure. Specifically, the inboard MSIV closure time acceptance criteria contained in Functional Test Procedure 0255-07-IA-2, Main Steam Isolation Valve Functional Checks Test, did not account for the elevated containment pressure and the expected lower pneumatic supply pressure expected during design basis accidents.re expected during design basis accidents.  +
23:59:59, 30 September 2018  +
05000263  +
23:59:59, 30 September 2018  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05:30:17, 4 December 2018  +
23:59:59, 30 September 2018  +
Inboard Main Steam Isolation Valve Closure Time Test Acceptance Criteria Did Not Account for the Design Basis Accident Containment Back Pressure and Pneumatic Supply Operating Pressure  +