Browse wiki
Jump to navigation
Jump to search
The inspectors identified a Green non-cite … The inspectors identified a Green non-cited violation (NCV) of Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Appendix B, Criterion III, Design Control, when Exelon failed to ensure that adequate design control measures existed to verify the adequacy of the Reactor Vessel Level Monitoring System (RVLMS) uncertainty calculation. Specifically, Exelon failed to identify errors in the RVLMS uncertainty calculation which resulted in a reasonable doubt of operability for the system after a temporary modification was implemented. a temporary modification was implemented. +
23:59:59, 30 June 2018 +
23:59:59, 30 June 2018 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000244/FIN-2018002-01 +, 05000244/FIN-2018002-01 +, 05000244/FIN-2018002-01 +, 05000244/FIN-2018002-01 +, 05000244/FIN-2018002-01 +, 05000244/FIN-2018002-01 +, 05000244/FIN-2018002-01 +, 05000244/FIN-2018002-01 +, 05000244/FIN-2018002-01 +, 05000244/FIN-2018002-01 +, 05000244/FIN-2018002-01 +, 05000244/FIN-2018002-01 +, 05000244/FIN-2018002-01 +, 05000244/FIN-2018002-01 +, 05000244/FIN-2018002-01 +, 05000244/FIN-2018002-01 +, 05000244/FIN-2018002-01 +, 05000244/FIN-2018002-01 +, 05000244/FIN-2018002-01 +, 05000244/FIN-2018002-01 +, 05000244/FIN-2018002-01 +, 05000244/FIN-2018002-01 +, 05000244/FIN-2018002-01 + and 05000244/FIN-2018002-01 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
22:35:12, 10 September 2018 +
23:59:59, 30 June 2018 +
Incorrect Scaling Factors in Reactor Vessel Level Monitoring System Instrumentation Uncertainty Calculation +