Semantic search

Jump to navigation Jump to search
 Issue dateFromTitleProject stage
CP-201401035, Relief Requests Nos. B-7, B-12 and B-13 for the Second 10-Year ISI Interval (Second ISI Interval Start Date: August 3, 2004; Second ISI Interval End Date: August 2, 2014)27 August 2014Luminant
Flores R
Madden F
Relief Requests Nos. B-7, B-12 and B-13 for the Second 10-Year ISI Interval (Second ISI Interval Start Date: August 3, 2004; Second ISI Interval End Date: August 2, 2014)Request
ML14266A20523 September 2014Division of Operating Reactor Licensing
Balwant Singal
NRR E-mail Capture - Acceptance Review - Request Requests B-7, B-12, and B-13, Comanche Peak Nuclear Power Plant, Unit 2Acceptance Review
ML14350B37016 December 2014Balwant Singal
Plant Licensing Branch IV
NRR E-mail Capture - Request for Additional Information - Relief Requests (Rrs) B-7, B-12, and B-13RAI
CP-201500032, Response to Request for Additional Information for Relief Requests B-7, B-12, and B-138 January 2015Luminant
Flores R
Madden F
Response to Request for Additional Information for Relief Requests B-7, B-12, and B-13Response to RAI
ML15090A1043 April 2015Markley M
Plant Licensing Branch IV
Relief Requests B-7, B-12, and B-13 - Steam Generator Head-to-Tube Sheet Welds for the Second 10-Year Inservice Inspection IntervalOther