Semantic search
Jump to navigation
Jump to search
Issue date | From | Title | Project stage | |
---|---|---|---|---|
NOC-AE-10002592, Request for Relief from ASME Section Xl Code Requirements for Steam Generator Nozzle Non-Destructive Examination (Relief Request RR-ENG-3-01) | 20 September 2010 | South Texas Ruvalcaba M | Request for Relief from ASME Section Xl Code Requirements for Steam Generator Nozzle Non-Destructive Examination (Relief Request RR-ENG-3-01) | Request |
ML102990029 | 25 October 2010 | Thadani M Plant Licensing Branch IV | Acceptance Review Email, Relief Request RR-ENG-3-01, RR-ENG-3-02, and RR-ENG-3-03 from ASME Code Requirements for Third 10-Year Inservice Inspection Interval (TAC ME4766-ME4767, ME4764-ME4765, ME4762-ME4763) | Acceptance Review |
ML103010315 | 28 October 2010 | Thadani M Plant Licensing Branch IV | Request for Additional Information Email, Relief Request RR-ENG-3-01, from ASME Code Requirements for Class 2 Piping for the Third 10-Year Inservice Inspection Interval | RAI |
ML110980347 | 20 April 2011 | Markley M Plant Licensing Branch IV | Relief Request RR-ENG-3-01, from ASME Code Requirements for Steam Generator Main Steam Nozzle Non-Destructive Examination, Third 10-Year Inservice Inspection Interval | Other |