ML20236C30414 September 1976Jaffe D
Office of Nuclear Reactor Regulation
Notification of 760928 Meeting W/Util in Bethesda,Md to Discuss Util Concepts for Proposed Neutron Shield for Plant. Summary of Neutron Streaming Problem EnclMeeting
ML20064C23411 October 1978NORTHEAST UTILITIES
Counsil W
Forwards Proposed Tech Specs to Require Diesel Generator Start Time of Less than or Equal to 20Other
ML20064D4921 November 1978NORTHEAST UTILITIES
Counsil W
Presents Details of Stretch Power Effort in Advance of Execution to Enable Facility to Operate at 2,700 Mwt Following Second Refueling OutageOther
ML20064E45318 November 1978Nebraska Public Power District
Counsil W
Forwards Sys Description for Reactor Coolant Pump Shaft Speed Trip Function Being Installed by Util to Replace Steam Generator Differential Pressure Sys.Believes Proposal Is Exempt from Amend FeeOther
ML20062G38714 December 1978NORTHEAST UTILITIESSleeved Guide Tube Inspec Prog, CEN-104(N)-NP.Describes Inspec Prog to Show Performance Re Wear.Edited to Delete Info W/Held from Pub Disclosure IAW 10CFR2.790Other
ML20064H42915 December 1978NORTHEAST UTILITIES
Counsil W
Appl to Amend Oper Lic DPR-65 by Increasing Maximum Allowable Thermal Output of Subj Facil Over 2700MWt to Commence W/Cycle 3 on 790515.W/att Environ Impact Appraisal, Eval of Radiological Consequences & Site MeteorologyOther
ML20062G38118 December 1978NORTHEAST UTILITIES
Counsil W
Forwards non-proprietary Version of Sleeved CEA Guide Tube Inspec Prog,CEN-104(N)-NP,relating to Amend 38 to DPR-65. IAW 10CFR2.790.W/encl AffidavitOther
ML20244A54823 March 1979NORTHEAST UTILITIES
Counsil W
Provides Trip Setpoint for Proposed Tech Spec Revision to Incorporate Reactor Coolant Pump Speed Sensing Sys as Addition to Reactor Protection SysOther
ML20076A8026 April 1979NORTHEAST UTILITIES
Counsil W
in Answer to IE Bulletin 79-01,environmentally Qualified stem-mounted Limit Switches W/Appropriate Documentation Can Be Procured.Util Will Replace Switches W/Qualified Switches Prior to Start of Cycle 3 Operation Scheduled for May 1979Other
ML20244A58512 April 1979Counsil W
Northeast Nuclear Energy
Forwards Info Re Proposed Revisions to Tech Specs to Reflect Installation of Reactor Coolant Pump Speed Sensing Sys to Provide Protection for 4-pump Loss of Flow EventOther
ML20076A84313 April 1979NORTHEAST UTILITIESSteam Generator InspOther
ML20076A83613 April 1979NORTHEAST UTILITIES
Counsil W
Eddy Current Test Has Been Performed.No Tube Defects Discovered & No Corrective Action Based on Tube Defects Required.Preliminary Analysis of Results of Insp Indicates Denting Rate Has Been ReducedOther
ML20076A90418 April 1979NORTHEAST UTILITIES
Counsil W
Responds to IE Bulletin 79-01.One Solenoid Installed on safety-related Valve in Plant Containment Has Not Been Qualified for Svc in LOCA Environ.Solenoid Will Be Replaced Before Start of Cycle 3 OperationOther
ML20076A95526 April 1979NORTHEAST UTILITIES
Counsil W
Responds to NRC 780419 Request for Insulation Resistance Tests.Forwards Electrical Penetration Testing Evaluation. Modified Conductor Configuration Is Acceptable for Cycle 3 OperationRequest
ML20076A95226 April 1979NORTHEAST UTILITIES
Counsil W
Discusses Guide Tube Insp Program.Pull Tests Performed on 35 Sleeves.Evaluation of Data Indicates Sleeves Are Functioning as ExpectedOther
ML20244A6133 May 1979NORTHEAST UTILITIES
Counsil W
Forwards Responses to Request for Addl Info Re Cycle 3 Safety Analysis.Nonproprietary Rept Encl.Proprietary Version Withheld (Ref 10CFR2.790)Request
ML20076B0878 May 1979NORTHEAST UTILITIES
Counsil W
Switzer D
Notifies That stem-mounted Limit Switches on Valves SI-614, SI-624,SI-634 & SI-644 Will Not Be Replaced;Valves Do Not Perform safety-related FunctionOther
ML20076B08811 May 1979NORTHEAST UTILITIES
Counsil W
Switzer D
Discusses Results of Six Tasks Which Utilized Adlpipe Computer Program for Reanalysis of Piping Sys.Mods Involved Minor Changes to Small Portions of Existing SysOther
ML20076B08917 May 1979NORTHEAST UTILITIES
Counsil W
Forwards Addl Info Re Performance of Control Element Assembly Guide Tubed Sleeves,In Response toOther