Semantic search

Jump to navigation Jump to search
 Entered dateEvent description
ENS 556987 January 2022 16:29:00The following information was provided by the licensee via email: At 1223 CST on January 7, 2022, Callaway Plant was in Mode 1 at approximately 100 percent power when a turbine trip / reactor trip occurred. All safety systems responded as expected with the exception of an indication issue with the 'B' Feedwater Isolation Valve, which was confirmed closed. A valid Feedwater Isolation Signal and Auxiliary Feedwater Actuation Signal were also received as a result of the reactor trip. The plant is being maintained stable in Mode 3. All control rods fully inserted from the reactor trip signal, and decay heat is being removed via the Auxiliary Feedwater and Steam Dump Systems. The NRC Senior Resident Inspector was notified. The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance: The plant is in a normal shutdown electrical lineup.