Semantic search
Entered date | Event description | |
---|---|---|
ENS 47375 | 25 October 2011 13:07:00 | At approximately 1115 EDT on 10/25/11 an intern entered the dry gamma room at the Rhode Island Nuclear Science Center Facility during an ion probe calibration procedure. The intern received an estimated unplanned dose of between 2-3 rem based on a stay time of 5 minutes in a 500 mr/min field. His dosimetry, an OSL (Optically Stimulated Luminescence) badge, has been sent to Landauer for expedited processing. The dry gamma room is properly posted as a high radiation area with administrative controls in effect to limit access. The assistant Director of the facility is performing an investigation including event reconstruction to determine the cause.
The licensee clarified that the call to the Operations Center made on 10/25/11 was a 24 hour notification required by the facility's Technical Specification 1.25.8 based on the potential for over-exposure. NRR Backup Project Manager (Hardesty) notified. |