ENS 4983718 February 2014 11:55:00The four Main Steam Line Radiation Monitors 3MSS*RE75, 3MSS*RE76, 3MSS*RE77 and 3MSS*RE78 along with Terry Turbine Aux Feedwater Steam Exhaust Radiation Monitor 3MSS*RE79 will be removed from service to support a scheduled design change. This condition is reportable per 10CFR50.72(b)(3)(xiii). This equipment is expected to be restored to service within 72 hours. The licensee informed the NRC Resident Inspector.
ENS 473205 October 2011 15:24:00At 0812 EDT on October 5, 2011, Millstone Power Station determined that a condition exists affecting Emergency Preparedness Capabilities due to a major loss of offsite communications capability. Specifically, Millstone Power Station was notified by an offsite vendor that the system relied upon for offsite communications in accordance with the Millstone Emergency Plan using a pager system is not functioning reliably. The Millstone Emergency Plan will be implemented by the approved, pre-existing alternate notification method. Appropriate officials are being notified that the alternate method is being employed until the primary means is restored. This condition is being reported pursuant to 10 CFR 50.72(b)(3)(xiii). The paging system is being repaired and the utility has an alternate communication method in place. The NRC Senior Resident Inspector has been notified as well as Waterford local government and the Connecticut Department of Environmental Protection. IRF Number: 2011066