 Entered dateEvent description
ENS 5031427 July 2014 15:22:00VEGP (Vogtle Electric Generation Plant) Unit One was at 100 percent power, with a Main Feed Pump (MFP) Turbine A trip mechanism test in-progress, when MFP A Trip alarm was received in the Main Control Room. Control Room crew identified MFP A speed and steam generator levels lowering and initiated a manual reactor trip. All control rods fully inserted and nothing unusual was noted. Auxiliary feed water and feedwater isolation actuated as expected. The unit is currently stable in MODE 3 at normal operating temperature and pressure. A forced outage response team has been formed to determine the cause of the MFP A trip and determine restart criteria and time of restart. The unit is in a normal shutdown electric plant lineup. No effect on Unit 2. The licensee notified the NRC Resident Inspector.
ENS 500068 April 2014 05:21:00VEGP Unit 2 was at 100% power, normal activities, when digital feedwater trouble alarms were received on all 4 steam generators (SG) with level stable in all generators. Operating crew entered abnormal operating procedure for feedwater malfunction when SG #3 level began rapidly lowering. Operators attempted to take manual control of SG #3 main feedwater regulating valve and were unable to raise SG #3 level. SG #3 level lowered to the Lo-Lo Level setpoint causing an automatic reactor trip. All control rods fully inserted and SG #3 level remained off scale low on narrow range indications. Auxiliary feedwater and feedwater isolation actuated as expected. (Unit 2) is currently stable in Mode 3 at normal operating temperature and pressure. A forced outage response team has been formed to determine the cause of the low SG water level and determine restart criteria and time of restart. All control rods fully inserted on the trip. Decay heat is being removed via auxiliary feedwater to steam generators steaming to the condenser steam dumps. The licensee has notified the NRC Resident Inspector.
ENS 4945319 October 2013 09:36:00VEGP (Vogtle Electric Generating Plant) unit two was at 100% power, normal activities, when the unit two turbine tripped causing an automatic reactor trip. All control rods fully inserted and nothing unusual was noted. Auxiliary feed water and feedwater isolation actuated as expected. The unit is currently stable in Mode 3 at normal operating temperature and pressure. A forced outage response team has been formed to determine the cause of the turbine trip and determine restart criteria and time of restart. During the transient, no relief valves lifted. The electrical grid is stable and supplying plant safety loads. Decay heat is being removed via steam dumps to the condenser. The licensee has notified the NRC Resident Inspector.