Semantic search

Jump to navigation Jump to search
 Entered dateEvent description
ENS 405602 March 2004 09:48:00The license received a 20 box shipment of fuel sipping equipment from Framatone ANP, Inc out of Richland, WA. One of the 20 boxes was determined to have an external surface contact reading >200 millirem (actual reading 202 millirem). The box was opened and contents surveyed resulting in a reading of 400 millirem/hr coming from a support stand that was in the package. A hot particle was captured from the stand and properly disposed of with their rad waste. After the particle had been removed, the stand, readings went from 400 millirem/hr to 20 millirem/hr. The licensee notified Framatone ANP about the incident. The Resident Inspector was notified