 Issue dateTitleFromTo
NRC Generic Letter 1995-0717 August 1995NRC Generic Letter 1995-007: Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate ValvesCrutchfield D
Office of Nuclear Reactor Regulation
ML17353A41811 October 1995Provides Initial Response to GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power-Operated Gate Valves.NextEra Energy
Plunkett T
Office of Information Resources Management
ML17353A46129 November 1995Forwards Response to Request for Addl Info Re Closure of GL 89-10, Safety-Related Motor-Operated Valve Testing & Surveillance.NextEra Energy
Hovey R
Office of Information Resources Management
Information Notice 1996-05, Partial Bypass of Shutdown Cooling Flow from Reactor Vessel18 January 1996Partial Bypass of Shutdown Cooling Flow from Reactor VesselCrutchfield D
Office of Nuclear Reactor Regulation
Information Notice 1996-08, Thermally Induced Pressure Locking of a High Pressure Coolant Injection Gate Valve5 February 1996Thermally Induced Pressure Locking of a High Pressure Coolant Injection Gate ValveCrutchfield D
Office of Nuclear Reactor Regulation
ML17353A5589 February 1996Forwards Response to GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power-Operated Gate Valves.NextEra Energy
Hovey R
Office of Information Resources Management
ML18151A41425 June 1996Addendum a to Rev 0 to ME-0498, Pressure Locking & Stem Effect Thermal Binding Analysis for GL 95-07.Dominion
Demars B
Wolak J
Jones P
ML18152A1943 July 1996Forwards Response to Request for Addl Info Re GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power-Operated Gate Valves. Calculations ME-0456 & ME-0498 Also EnclDominion
Ohanlon J
Office of Information Resources Management
ML17353A82930 July 1996Responds to RAI Re GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power-Operated Gate Valves.NextEra Energy
Hovey R
Office of Information Resources Management
Information Notice 1996-49, Thermally Induced Pressurization of Nuclear Power Facility Piping20 August 1996Thermally Induced Pressurization of Nuclear Power Facility PipingMartin T
Office of Nuclear Reactor Regulation
Information Notice 1997-07, Problems Identified During Generic Letter 89-10 Closeout Inspections6 March 1997Problems Identified During Generic Letter 89-10 Closeout InspectionsMartin T
Office of Nuclear Reactor Regulation
ML17354A66118 September 1997Forwards Supplemental Response to GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power-Operated Gate Valves, to Support NRC ReviewNextEra Energy
Hovey R
Office of Information Resources Management