Semantic search

Jump to navigation Jump to search
 Issue dateTitleFromTo
NRC Generic Letter 1995-0717 August 1995NRC Generic Letter 1995-007: Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate ValvesCrutchfield D
Office of Nuclear Reactor Regulation
ML20093K78016 October 1995Responds to GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power Operated Gate ValvesLuminant
Terry C
Office of Information Resources Management
ML20094H2706 November 1995Provides Listed Clarification Re 90 Day Requested Actions Stated in GL 95-07, Pressure Locking & Thermal Binding of Safety Related Power Operated Gate ValvesLuminant
Terry C
Office of Information Resources Management
Information Notice 1996-05, Partial Bypass of Shutdown Cooling Flow from Reactor Vessel18 January 1996Partial Bypass of Shutdown Cooling Flow from Reactor VesselCrutchfield D
Office of Nuclear Reactor Regulation
Information Notice 1996-08, Thermally Induced Pressure Locking of a High Pressure Coolant Injection Gate Valve5 February 1996Thermally Induced Pressure Locking of a High Pressure Coolant Injection Gate ValveCrutchfield D
Office of Nuclear Reactor Regulation
ML20100F27613 February 1996Rev 0 of Engineering Rept, Resolution of NRC GL 95-07 'Pressure Locking & Thermal Binding of Safety-Related Power- Operated Gate Valves.'Luminant
Meyer J
Brau J
Chiu P
ML20100F26913 February 1996Forwards Rev 0 of Engineering Rept ER-ME-102, Resolution of NRC GL 95-07 'Pressure Locking & Thermal Binding of Safety- Related Power-Operated Gate Valves.'Luminant
Terry C
Kelley J
Office of Information Resources Management
ML20116A01418 July 1996Responds to RAI Re GL 95-07, Pressure Locking & Thermal Binding of SR Power Operated Gate ValvesLuminant
Terry C
Office of Information Resources Management
Information Notice 1996-49, Thermally Induced Pressurization of Nuclear Power Facility Piping20 August 1996Thermally Induced Pressurization of Nuclear Power Facility PipingMartin T
Office of Nuclear Reactor Regulation
Information Notice 1997-07, Problems Identified During Generic Letter 89-10 Closeout Inspections6 March 1997Problems Identified During Generic Letter 89-10 Closeout InspectionsMartin T
Office of Nuclear Reactor Regulation
ML20137C26814 March 1997Responds to GL 95-07, Pressure Locking & Thermal Binding of SR Power Operated Gate ValvesLuminant
Walker R
Terry C
Office of Information Resources Management
ML20154B57430 September 1998Safety Evaluation Re Licensee Response to GL 96-05, Periodic Verification of Design-Basis Capability of Safety- Related Motor-Operated Valves. Licensee Has Established Acceptable ProgramNRC (Affiliation Not Assigned)
IR 05000445/19990037 April 1999Insp Repts 50-445/99-03 & 50-446/99-03 on 990124-0306.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant SupportNRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
ML20195B63525 May 1999Submits Response to RAI Re GL 95-07, Pressure Locking & Thermal Binding of Safety Related Power Operated Gate ValvesLuminant
Walker R
Terry R
Office of Information Resources Management
ML20195J06514 June 1999Submits Response to RAI Re GL 95-07, Pressure Locking & Thermal Binding of Safety Related Power Operated Gate ValvesLuminant
Walker R
Terry C
Office of Information Resources Management
ML20209H75015 July 1999Forwards Safety Evaluation on GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power-Operated Gate Valves, for Comanche Peak Steam Electric Station,Units 1 & 2NRC (Affiliation Not Assigned)
Jaffe D
Terry C
TEXAS UTILITIES CO.
ML20209H76615 July 1999Safety Evaluation Accepting GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power-Operated Gate Valves, for Comanche Peak Steam Electric Station,Units 1 & 2NRC (Affiliation Not Assigned)
IR 05000445/199901414 September 1999Insp Repts 50-445/99-14 & 50-446/99-14 on 990707-0821.Four Violations Occurred & Being Treated as Ncvs.Major Areas Inspected:Operations,Maint,Engineering & Plant SupportNRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
CPSES-200201911, Letter from Roger D. Walker Re Comanche Peak Steam Electric Station Completion of Generic Letter 95-07 Activities for Unit 21 May 2002Letter from Roger D. Walker Re Comanche Peak Steam Electric Station Completion of Generic Letter 95-07 Activities for Unit 2Walker R
TXU Energy
Office of Nuclear Reactor Regulation
Document Control Desk
CPSES-200203913, Completion of Generic Letter 95-07 Activities for Unit 14 December 2002Completion of Generic Letter 95-07 Activities for Unit 1Walker R
TXU Energy
Office of Nuclear Reactor Regulation
Document Control Desk
ML07249031031 August 2007WCAP-16840-NP, Rev. 0, Comanche Peak Nuclear Power Plant Stretch Power Uprate Licensing Report, Cover to Page 2.7.7-5WestinghouseOffice of Nuclear Reactor Regulation
ML08151017327 June 2008Issuance of Amendment Nos. 146 and 146, Stretch Power Uprate, Revision to TS 1.0, Use and Application, to Revise Rated Thermal Power from 3458 to 3612 MwtBalwant Singal
NRC/NRR/ADRO/DORL/LPLIV
Luminant
Blevins M