Semantic search
Jump to navigation
Jump to search
Issue date | Title | From | To | |
---|---|---|---|---|
ML20138M389 | 12 December 1985 | Topical Rept Evaluation of Rev 1 to BAW-1847, Leak Before Break Evaluation of Margins Against Full Break for Rcs.... Rept Presents Acceptable Justification to Eliminate Dynamic Effects of Large Ruptures in Piping | Office of Nuclear Reactor Regulation | |
ML20137Y058 | 18 February 1986 | Requests facility-specific Info Re Requests for Exemption from GDC 4,concerning Protection Against Dynamic Loads Resulting from Postulated Breaks of Primary Main Loop Piping.Info Re Leakage Detection Sys Should Be Included | Stolz J Office of Nuclear Reactor Regulation | Reinaldo Rodriguez SACRAMENTO MUNICIPAL UTILITY DISTRICT |
ML20137Y043 | 18 February 1986 | Discusses Safety Evaluation of B&W Owners Group Repts Dealing W/Elimination of Postulated Pipe Breaks in PWR Primary Main Loops.Exemption from GDC 4 & Demonstration That Leakage Sys in Compliance W/Reg Guide 1.45 Needed | Stolz J Office of Nuclear Reactor Regulation | Duke Energy Wilgus W |
ML20154M259 | 18 February 1986 | Discusses SER of Rev 1 to BAW-1847 & BAW-1889P Re Elimination of Postulated Pipe Breaks in PWR Primary Main Loops.Repts Acceptable.Leakage Detection Sys Info Requested | Berkow H Office of Nuclear Reactor Regulation | Jackie Cook Consumers Energy |
NRC Generic Letter 1989-21 | 19 October 1989 | NRC Generic Letter 1989-021: Request for Information Concerning Status of Implementation of Unresolved Safety Issue (USI) Requirements | Partlow J Office of Nuclear Reactor Regulation |