ML0924500803 August 2009Report No. 0800692.404, Rev. 1, Design Report for Preemptive Repairs of Hot Leg Alloy 600 Components, San Onofre Nuclear Generating Station, Units 2 & 3.Non-Destructive Examination
Weld Overlay
Finite Element Analysis
Intergranular Stress Corrosion Cracking
Stress corrosion cracking
Code Reconciliation
Liquid penetrant
Dissimilar Metal Weld
ML08364037523 January 2009Relief Requests ISI-3-27, Revision 1, and ISI-3-28, Revision 1, for the Application of Weld Overlay on Dissimilar and Similar Metal WeldsNon-Destructive Examination
Weld Overlay
Incorporated by reference
Dissimilar Metal Weld
Thermal fatigue
ML08322013112 November 2008Revision to Third Ten-Year Inservice Inspection (ISI) Interval Requests ISI-3-27 and ISI-3-28, Use of Structural Weld Overlay and Associated Alternative Repair TechniquesNon-Destructive Examination
Weld Overlay
Nondestructive Examination
Intergranular Stress Corrosion Cracking
Stress corrosion cracking
Liquid penetrant
Dissimilar Metal Weld
Thermal fatigue
ML07325000413 December 2007RR ISI-3-27 - Approval to Use Alternatives to the Requirements of ASME Code for Repair/Replacement Activities Related to Performance of Structural Weld Overlays (TACs MD4580 & MD4581)Weld Overlay
Nondestructive Examination
Incorporated by reference
Liquid penetrant
Dissimilar Metal Weld
Thermal fatigue
ML07268084321 September 2007Response to Request for Additional Information Regarding Third Ten-Year Inservice Inspection (ISI) Interval Relief Request ISI-3-27Non-Destructive Examination
Weld Overlay
Stress corrosion cracking
Liquid penetrant
Dissimilar Metal Weld
DM weld
ML0721500461 August 2007Third Ten-Year Inservice Inspection (ISI) Interval Request ISI-3-28 48-Hour Hold PeriodNon-Destructive Examination
Weld Overlay
Stress corrosion cracking
Dissimilar Metal Weld
Thermal fatigue
ML07138001312 June 2007Relief Request ISI-3-25 - Third 10-Year Inservice Inspection Interval Re Use of Structural Weld Overlay and Associated Alternative Repair TechniquesWeld Overlay
Nondestructive Examination
Incorporated by reference
Intergranular Stress Corrosion Cracking
Dissimilar Metal Weld
ML07137074012 June 2007Relief Request ISI-3-24 Third 10-Year ISI Interval Regarding Four Reactor Coolant System Pressurizer, Dissimilar Metal, Nozzle-to-safe-end Welds Structural Overlay & Alternative Repair TechniquesWeld Overlay
Nondestructive Examination
Incorporated by reference
Intergranular Stress Corrosion Cracking
Dissimilar Metal Weld
ML07057043321 February 2007Third Ten-Year Inservice Inspection (ISI) Interval Relief Request ISI-3-27 Use of Structural Weld Overlay and Associated Alternative Repair TechniquesNon-Destructive Examination
Weld Overlay
Nondestructive Examination
Intergranular Stress Corrosion Cracking
Stress corrosion cracking
Liquid penetrant
Dissimilar Metal Weld
Thermal fatigue
ML07037063020 February 2007Correction Letter for Issuance for Request for Relief Relief Request ISI-3-18, from the Requirements of the American Society of Mechanical Engineers Boiler and Pressure Vessel CodeWeld Overlay
Nondestructive Examination
ML06311032214 December 2006Request for Relief (RR ISI-3-18) from the Requirements of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code - Third 10-Year ISI IntervalWeld Overlay
Nondestructive Examination
Incorporated by reference
Stress corrosion cracking
Eddy Current Testing
Liquid penetrant
Dissimilar Metal Weld
Thermal fatigue
ML06298020323 October 2006Additional Information Supporting the Third Ten-Year Inservice Inspection Interval Relief Request ISI-3-24 and ISI-3-25 for the Use of Structural Weld Overlay and Associated Alternative Repair TechniquesNon-Destructive Examination
Weld Overlay
ML06276023329 September 2006Additional Information Supporting Third Ten-Year Inservice Inspection (ISI) Interval Relief Requests ISI-3-24 and ISI-3-25 for the Use of Structural Weld Overlay and Associated Alternative Repair TechniquesWeld Overlay
Nondestructive Examination
Liquid penetrant
Dissimilar Metal Weld
ML06249023612 September 2006Request for Additional Information on Relief Request ISI-3-24, Use of Structural Weld Overlay and Associated Alternative Repair TechniquesWeld Overlay
Nondestructive Examination
Liquid penetrant
ML06199011114 July 2006Third Ten-Year Inservice Inspection Interval Request ISI-3-25 Use of Structural Weld Overlay and Associated Alternative Repair TechniquesWeld Overlay
Nondestructive Examination
Intergranular Stress Corrosion Cracking
Stress corrosion cracking
Liquid penetrant
Dissimilar Metal Weld
Thermal fatigue
ML06184046430 June 2006Third Ten-Year Inservice Inspection Interval Relief Request ISI-3.24 Use of Structural Weld Overlay and Associated Alternative Repair TechniquesWeld Overlay
Nondestructive Examination
Intergranular Stress Corrosion Cracking
Stress corrosion cracking
Liquid penetrant
Dissimilar Metal Weld
Thermal fatigue
ML06135041210 May 2006Weld Overlay Design and Analysis for Pressurizer Safety Relief and Spray Nozzle-to-Safe End Welds in Support of ISI-3-18Weld Overlay
Finite Element Analysis
Stress corrosion cracking
Liquid penetrant
Dissimilar Metal Weld
ML0611003667 March 2006SONGS 2, Email, N. Kalyanam to Jack Rainsberry, Draft RAI from Dci/Cfeb on ISI-3-18Weld Overlay
Stress corrosion cracking
ML06055042322 February 2006Uni 2, Third Ten-Year Inservice Inspection (ISI) Interval Relief Request ISI-3-18 Use of Structural Weld Overlay and Associated Alternative Repair Techniques,Weld Overlay
Nondestructive Examination
Intergranular Stress Corrosion Cracking
Stress corrosion cracking
Liquid penetrant
Dissimilar Metal Weld
Affidavit
Thermal fatigue