 Issue dateTitleTopic
ML20040H48410 February 1982Ro:On 820111,automatic Starter Circuit Failed to Start Emergency Generator on Loss of Site Electrical Power.Caused by Inability of Generator Choke to Compensate for Lower Ambient Temp Due to Extreme Cold Weather
ML20009D52829 June 1981Ro:On 810601,during Semiannual Compliance Check,Low Flow Scram Set Point on Pool Coolant Flow Instrument 921B Was Below Tech Specs.Scram Trip Unit Replaced & Compliance Check Performed
ML20004B90326 May 1981Ro:On 810518,pressurizer High Pressure Scram Switch 939 Was Found Isolated.Caused by Failure to Reopen Valve 599B After Insp.Valve 599B Reopened & High Pressure Scram Protection Restored
ML20004B03018 May 1981Ro:On 810420,meter Control Relay Unit Scram Did Not Actuate in Response to Low Pressure Signal.Caused by Reduced Capacitance Value Preventing Capacitor from Charging Sufficiently.New Meter Relay Control Unit Installed
ML20003D67620 March 1981Ro:On 810223,w/reactor Shutdown for Scheduled Maint, Isolation Valve for Containment Bldg Leak Rate Determination Sys Found in Open Position.Cause Not Stated.Valve Lineup on Containment Leak Rate Sys Conducted.Pipe Cap Installed
ML19350B96917 March 1981Ro:On 810223,isolation Valve V546B Failed to Move to Fully Opened Position Following Normal Shutdown.Caused by Difficulty in Movement of Valve Actuator.Valve Rebuilt, Lubricated & Reinstalled
ML20003C83813 March 1981Ro:On 810213,while Performing Reactor Startup,Nuclear Instrumentation Channel 3 Failed to Respond Positively to Changes in Reactor Subcritical Multiplication.Caused by Faulty Cable Installation.Cables Were Properly Connected
ML20003B2635 February 1981Ro:On 810109 & 10,reactor Operated W/Low Air Flow Through Stack Radiation Monitor.Caused by Associated Air Blower in Secured Position.Blower Turned on When Found Secured.Stack Monitor Filters Pulled & Counted
ML19331D96029 August 1980Ro:On 800829,primary Inlet Isolation Valve 507B Failure to Shut When Securing Primary Sys Following Shutdown.Caused by Separation of Lower Seat from Metal Insert in Schrader Valve & Consequent Blockage of Exhaust Port
ML19331D95729 August 1980Ro:On 800803,entire Holding Tank Failed to Meet Primary Tech Specs.Caused by Inadvertent Entry of Approx 400 Gallons of Water Failing to Meet Primary Specs.Holdup Tank Drained & Water Meeting Primary Specs Returned to Tank
ML19320B4957 July 1980Ro:On 800616,while Verifying Sample Loading of triple-tubed Sample Irradiated Facility Located in Ctr Test Hole,One Tube Was Found Missing 2-inch Long Spacer.No Unreviewed Safety Question Existed During Period of Operation
ML19318D2524 June 1980Ro:On 800516,automatic Regulating Blade Drive Mechanism Failed.Caused by Worn Spot on Drive Gear.Gear Drive Assembly Replaced & Blade Cycled Through Full Travel to Assure Proper Operation
ML19310A3034 June 1980Ro:On 800516,w/reactor Operating at Full Power in Automatic Mode,Automatic Regulating Blade Drive Mechanism Was Discovered Producing Grinding Noise.Caused by Worn Spot on Drive Gear.Regulating Blade Gear Drive Was Replaced
ML19310A3632 June 1980Ro:On 800509,emergency Generator Failed to Start When Starting Sequence Was Initiated by Automatic Weekly Exerciser.Caused by Tripped Starter Motor.Generator Inspected & Retested W/New Starter Motor
ML19257D50922 January 1980Ro:On 791227,while Operating at Steady State Power Level, Fuse for Power Supply 2PS6 Was Removed.Reinstallation of Fuse Caused Reactor Scram from Temp Sensors 980A & 980B. Caused by Electrical Transient.Operator Admonished
ML19275A24227 September 1979Ro:On 790827,during Monthly Load Test,Emergency Generator Failed to Start.Cause Probably Due to Insufficient Fuel in Day Tank.Generator Inspected & Satisfactorily Retested
ML19331D96220 June 1975Ro:On 750620,investigation of Schrader 9725 Series three- Way Solenoid Valve Indicated Valve Could Fail If Lower Seal Separated from Metal Insert & Prevent Air from Being Exhausted.Mfg Confirmed Problem Through TestingLoctite