 SiteQuarterTitleDescription
05000390/FIN-2018002-02Watts Bar2018Q2Licensee-Identified ViolationLER: 05000390, 391/2017-013-00, Incorrectly Adjusted Auxiliary Building Gas Treatment System Damper Leads to a Condition Prohibited by Technical Specifications, November 6, 2017. Violation: Watts Bar Unit 1 TS 3.7.12, Auxiliary Building Gas Treatment System (ABGTS), Condition A, requires that an inoperable ABGTS train to be restored to operable status within 7 days. Condition B of TS 3.7.12 requires the plant to be in Mode 3 within 6 hours and Mode 5 within 36 hours if one train of ABGTS is inoperable longer than 7 days. Contrary to the requirements of TS 3.7.12, ABGTS, train A was determined to be inoperable from July 7, 2017, at 2030 Eastern Daylight Time (EDT) to September 5, 2017, at 1645 EDT while the plant remained in Mode 1. Significance/Severity Level: This violation was characterized using traditional enforcement because the NRC determined that this violation was not reasonably foreseeable and preventable by the licensee and, therefore, is not a performance deficiency. The violation was assessed using Sections 2.2.4 and 6.1.d.1 of the NRCs Enforcement Policy and determined to be a SL IV violation. Corrective Action Reference(s): Condition Report (CR) 1335791
05000327/FIN-2018001-03Sequoyah2018Q1Licensee-Identified ViolationThis violation of very low safety significant was identified by the licensee and has been entered into the licensee corrective action program and is being treated as a Non-Cited Violation, consistent with Section 2.3.2 of the Enforcement Policy.Violation: Sequoyah Unit 1 and Unit 2 Technical Specification 3.7.12, Auxiliary Building Gas Treatment System (ABGTS), requires two ABGTS trains be operable in modes 1, 2, 3, and 4. Contrary to the above, from March 3-7, 2017, the licensee blocked open door A212 resulting in the inoperability of the auxiliary building secondary containment enclosure boundary and thus inoperability of both trains of the ABGTS. Significance/Severity Level: Green. Using Inspection Manual Chapter 0609, Appendix A, The Significance Determination Process (SDP) for Findings At-Power, dated June 19, 2012, the inspectors determined that this finding was of very low safety significance (Green) because the finding only represents a degradation of the radiological barrier function provided for the auxiliary building.Corrective Action Reference: CR1269767
05000390/FIN-2009003-02Watts Bar2009Q2Licensee-Identified ViolationTS 3.7.12 required that two trains of the Auxiliary Building Gas Treatment System (ABGTS) be operable in Modes 1, 2, 3, and 4 and during movement of irradiated fuel assemblies in the fuel handling area. Contrary to this, on May 28, 2009 the A train of ABGTS was found to be inoperable, and on May 30, 2009 the B train was also found to be inoperable. This was identified in the licensees CAP as PER 164765. This finding is of very low safety significance because it only represented a degradation of the radiological barrier function provided for the auxiliary building