 Start dateReporting criterionTitleEvent descriptionSystemLER
ENS 542087 August 2019 04:00:00Agreement StateAgreement State Report - Shutter Stuck Open in Damaged Level Density GaugeThe following was received from KY Department for Public Health & Safety, Radiation Health Branch (KY RHB) via fax: KY RHB was notified by telephone on 8/8/19 by a representative from a specifically licensed facility, North American Stainless, that on 8/7/19 an event occurred when molten steel escaped a mold due to an overflow in a cooling trough, and covered access to the top portion of a Berthold Model LB300ML level gauge (Serial No. 9413), containing a 1 mCi Co-60 rod sealed source (Serial No 1820-11-5). This resulted in the shutter on-off mechanism becoming disabled. After the steel and mold had cooled, it was freed on 8/8/19 and segregated into a secure storage area. Initial readings taken with a Ludlum 2241-3 survey instrument measured with a Ludlum 44-7 probe were less than 2 mR/hr outside the gauge storage area. No overexposures were reported. On 8/8/19, Radiametric Technologies, a service provider located in Lorain, Ohio, requested reciprocal approval and was granted reciprocity on 8/9/19 in order to assess and remediate the situation, to be conducted on 8/13/19. North American Stainless is reviewing the incident to avoid future repeat incidents involving mold flow issues, and a complete report will be provided once the remediation is complete. Event Report ID No KY190007
ENS 5387110 February 2019 05:00:00Agreement StateAgreement State Report - Gauge Device Damaged by Molten SteelThe following report was received from the Commonwealth of Kentucky via fax: KY RHB (Kentucky Radiation Health Branch) was notified by telephone on 2/12/2019 at 1315 EST by a representative from a specifically licensed facility, North American Stainless, that on Sunday, 2/10/2019, North American Stainless encountered a 'breakout' when molten steel escaped and poured onto billet caster molds located below a 'tundish' filled with molten steel. One of the molds attached to a Berthold Model No. LB300ML Mold Level Control fixed gauging device, serial number 9415, containing 1 mCi (37 MBq) Co-60 (source serial number 1819-11-15) was covered with the liquid steel encapsulating the source holder. After the steel and mold had cooled, it was freed on 2/12/2019 and segregated. The encapsulating steel rendered the device on-off mechanism (shutter) inoperable. Initial readings taken with a Ludlum 2241-3 survey instrument measured 6.25 mR/hr measured 12 inches directly in front of the window, and 1.25 mR/hr measured 90 degrees from the line of the window measured at a distance of 12 inches. Readings at the back of the source holder were 132 microR/hr measured at a distance of 12 inches. No overexposures have been reported. On 2/12/2019, Radiametric Technologies, a service provider located in Lorain, Ohio, requested reciprocal approval and was granted reciprocity on 2/13/2019 in order to assess and remediate the situation. The fixed gauging device involved in the incident was recently leak tested (test conducted on 7/31/2018) by Suntrac Services, League City TX. Radiametric Technologies, Lorain OH, recently tested the source holder on-off mechanism (1/31/2019) and it was found to be in good working order. North American Stainless is reviewing the incident to avoid future incidents involving 'tundish' failures. A full report will be provided once the remediation is complete. Reporting criteria in 10 CFR 30.50(b)(2). KY Report #KY190001