ENS 4685516 February 2011 04:00:00Agreement StateAgreement State Report - Dose to Fetus During Thyroid ScanThe following report was received from the state via fax: A patient having a thyroid scan was administered 4 mCi of I-131 while in a pregnant condition. The circumstances under which the dose was administered are under investigation. The dose to the developing fetus is also under investigation. The whole body dose to the fetus is estimated to be 1 rad at this time. The discovery date (of 4/15/11) is an estimate. The real dose of discovery will be reported during the investigation. Also, the licensee was allowed 15 working days to issue a report to (the Massachusetts Radiation Control Program). (The Massachusetts Radiation Control Program) received that report on May 12, 2011.
ENS 4154217 January 2005 17:00:00Agreement StateMedical Misadministration - Wrong Treatment Site

The State provided the following NMED information: On 1/18/05, the licensee reported to the Agency a teletherapy misadministration that occurred on 1/17/05. The situation was described as 'the treatment field was displaced by six cm when the therapist set the central axis of the field at the tattoo marking the bottom of the field'. An area of 15 cm x 6 cm (treatment site) received dose when the plan called for that tissue to receive no dose. The dose was one day's treatment of 180 cGy. The treatment monitor units and energy were correct, the error was entirely an issue of field placement. The Regulation Code cited is 105 CFR 120.502 (4) (a). The intended dose to the patient was 180 cGy, however, only 90 cGy was given to the wrong treatment site (15 cm x 6 cm area). Per the treating physician, no corrective action is needed. The hospital retrained staff to ensure confirming proper positioning of therapy prior to treatment. Event type Description: MD2 - Wrong Treatment Site. Cause description: The therapist did not correctly align the treatment field with the patient's treatment alignment tattoo. The Agency considers this event closed.

  • * * UPDATE FROM STATE (TONY CARPENITO) TO M. RIPLEY AT 0953 EST 04/04/05 * * *

The following information was provided by the State via facsimile (State text in quotes): The device used to deliver the radiation treatment was a LINEAR ACCELERATOR. Notified R1 DO (Noggle) and NMSS EO (T. Essig)

  • * * RETRACTION FROM STATE (TONY CARPENITO) TO M. RIPLEY AT 1130 EST 04/04/05 * * *

Based on a discussion with the NMSS EO (T. Essig) and the State (T. Carpenito), this notification is retracted because the device used to deliver the radiation treatment is not regulated by NRC. Notified R1 DO (Noggle) and NMSS EO (T. Essig)